SLC1224 User’s Guide
Chapter 7 Diagnostic
79
SHDSL <port> Link
Up(SN=<seq no>):
<ds rate>/<us
rate>!
or
SHDSL Link Info:
NM:<ds NM>/<us NM>!
INFO
A SHDSL port established a connection.
<port> - port number
<seq no> - sequence number of the connection
<ds rate> - downstream rate
<us rate> - upstream rate
<us NM> - upstream noise margin
<ds NM> - downstream noise margin
SHDSL <port> Link
Down(SN=<seq no>)!
WARN
A SHDSL port lost its connection.
<port> - port number
<seq no> - sequence number of the connection
Session Begin!
INFO
A console, telnet or FTP session has begun (see the
<process> field for the type of session).
Session End!
INFO
A console telnet or FTP session has terminated (see the
<process> field for the type of session).
Incorrect Password!
WARN
Someone attempted to use the wrong password to start a
console, telnet or FTP session (see the <process> field
for the type of session).
Received Firmware
Checksum Error!
WARN
A checksum error was detected during an attempted
firmware upload (the <process> field shows whether the
web configurator or FTP was used).
Received Firmware
Size too large!
WARN
The file size was too large with an attempted firmware
upload (the <process> field shows whether the web
configurator or FTP was used).
Received Firmware
Invalid!
WARN
Someone attempted to upload a firmware file with a wrong
identity (the <process> field shows whether the web
configurator or FTP was used).
Received File <file>!
INFO
A file was uploaded to the line card by FTP.
<file> - received file’s name
THERMO OVER
TEMPERATURE:
dev:<id>
threshold:<threshold>
(degree C)
value:<temp> (degree
C)!
WARN
The temperature was too high at one of the three
temperature sensors.
<id> - 0: sensor near the power module
- 1: sensor near the CPU
- 2: sensor near the DSL chipset
<threshold> - threshold temperature
<temp> - temperature when the entry was logged
THERMO OVER
TEMPERATURE
released: dev:<id>
threshold:<threshold>
(degree C)
value:<temp> (degree
C)!
INFO
The temperature at one of the three temperature sensors
has come back to normal.
<id> - 0: sensor near the power module
- 1: sensor near the CPU
- 2: sensor near the DSL chipset
<threshold> - threshold temperature
<temp> - temperature when the entry was logged
Table 36
Log Messages (continued)
LOG MESSAGE
TYPE
DESCRIPTION
Содержание SLC1224
Страница 1: ...SLC1224 SHDSL Line Card User s Guide Version 3 50 11 2005 Edition 1...
Страница 2: ......
Страница 8: ...SLC1224 User s Guide 8 Customer Support...
Страница 14: ...SLC1224 User s Guide 14...
Страница 62: ...SLC1224 User s Guide 62 Chapter 3 G SHDSL Port Setup...
Страница 68: ...SLC1224 User s Guide 68 Chapter 5 Maintenance Figure 34 SLC Firmware Upgrade...
Страница 76: ...SLC1224 User s Guide 76 Chapter 6 Statistics...
Страница 82: ...SLC1224 User s Guide 82 Chapter 7 Diagnostic...