SW3
GIGABIT/FAST ETHERNET SWITCH TYPE SW3 (DIN)
76/122
USER GUIDE - M0SW3D1905Iv04 - V04 May 2019
•
Reauthentication attempts (reAuthMax).
It sets the maximum number of tries the
equipment will send to request reauthentication. Valid values are 1 to 10.
•
Quiet time after failure (quietPeriod).
It sets the period of time in which the
equipment will not request new tries once the maximum number of configured tries is
exceeded. Valid values, in seconds, are 1 to 65535.
•
IP address.
It sets the RADIUS server IP address.
•
UDP port.
It sets the UDP port to which the RADIUS client will send requests to the
server. The default value set in the standard is port 1812.
•
Shared secret.
It sets the password to be used to encode the communication with
the RADIUS server.
FIGURE 43
802.1x
submenu configuration page
5.15.2
MAC list
This submenu permits the authorized client MAC address list to be specified. The list may
or may not be activated in each port through the
Security type
parameter.
FIGURE 44
MAC list
submenu configuration page