Telnet and SSH servers can be disabled, although by default they are enabled. In addition,
in the case of the SSH server, both the service port and the idle timeout can be configured.
For this last parameter, valid values are 0 to 300 seconds. A value 0 for idle timeout means
that the feature is disabled.
FIGURE 20
Administration
menu configuration page
The procedure for the installation of the certificates is described in section B.4 of
5.3
LAN CONFIGURATION
The
LAN
menu has the IP parameters for the switch administration and management.
The switch also features running as a switch PVLAN (RFC 5517), see section 5.5.
The configuration parameters are the following:
•
Static IP.
When this control is selected, the equipment uses the data provided by the
user in relation to the IP address and its mask. The main IP address and its mask are
obtained automatically through the DHCP server.