Adjust the brightness on the suspension system by starting with the
lowest value and gradually increasing the brightness level. Please observe
the maximum permissible brightness (see Page 20).
•
Adjust the eyepieces (see Page 84).
•
Swing the surgical microscope over the surgical field into an ergonomic
position within the working distance.
WARNING
Eye damage
Looking directly at the light source, e.g., at the microscope lens or light guide,
can damage your eyes.
•
Never look directly at the light source!
CAUTION
Retinal injury to the patient’s eye!
Excessive light intensity or overly long exposure times may lead to retinal
damage in the patient’s eye.
•
Adjust the illumination intensity and the resulting radiation exposure time
by selecting the appropriate illumination setting. You will find the values
recommended by ZEISS in the table “Maximum radiation exposure times”
on Page 20.
•
When operating on the eye, use the retina protection filter (blue barrier
filter). It protects the patient’s retina against unnecessary (blue) radiation
and increases the recommended exposure time by factor 3.
•
If no red reflex is required, swing the retinal protection device into the
beam path.
CAUTION
Variable light intensity due to a faulty light source!
A faulty light source with variable light intensity can damage the patient’s retina.
•
Check the light source and the brightness adjustment before each use of
the device.
•
Keep a backup lamp or an OR illuminator ready at hand.
•
If the light control fails, switch the device to manual mode (see Page 131).
Содержание OPMI Lumera i
Страница 1: ...ZEISS OPMI Lumera i on the floor stand Instructions for Use G 30 1720 en Version 8 0 2018 11 26...
Страница 4: ...OPMI Lumera i Version 8 0 Page 4 G 30 1720 en...
Страница 25: ...Version 8 0 G 30 1720 en Page 25 OPMI Lumera i Safety measures Fig 2 Switch for manual mode 3 1 3...
Страница 32: ...Safety measures OPMI Lumera i Version 8 0 Page 32 G 30 1720 en...
Страница 35: ...Version 8 0 G 30 1720 en Page 35 OPMI Lumera i Device overview Fig 4 System overview 3 1 2...
Страница 37: ...Version 8 0 G 30 1720 en Page 37 OPMI Lumera i Device overview Fig 5 Components of the microscope 2 2 1 4 3...
Страница 39: ...Version 8 0 G 30 1720 en Page 39 OPMI Lumera i Device overview Fig 6 Controls on the microscope 2 3 4 1...
Страница 51: ...Version 8 0 G 30 1720 en Page 51 OPMI Lumera i Device overview Fig 15 Connectors on the floor stand 9 10 11 12...
Страница 61: ...Version 8 0 G 30 1720 en Page 61 OPMI Lumera i Preparation for use...
Страница 71: ...Version 8 0 G 30 1720 en Page 71 OPMI Lumera i Preparation for use Fig 24 C mount adapter 3 7 4 2 1 5 8 6...
Страница 83: ...Version 8 0 G 30 1720 en Page 83 OPMI Lumera i Preparation for use...
Страница 88: ...Preparation for use OPMI Lumera i Version 8 0 Page 88 G 30 1720 en...
Страница 97: ...Version 8 0 G 30 1720 en Page 97 OPMI Lumera i Operation...
Страница 99: ...Version 8 0 G 30 1720 en Page 99 OPMI Lumera i Operation Fig 35 Menu structure 2 3 7 6 5 4 1 8...
Страница 149: ...Version 8 0 G 30 1720 en Page 149 OPMI Lumera i Device data Fig 39 Dimensional drawing of OPMI Lumera i...
Страница 182: ...OPMI Lumera i Version 8 0 Page 182 G 30 1720 en...
Страница 183: ...Version 8 0 G 30 1720 en Page 183 OPMI Lumera i Blank page for your notes...