5-4
IM 701310-17E
Command
Function
Page
:ANALysis:FFT<x>:MEASure:PEAK[:
Queries the frequency value between peak values of the FFT computation. 5-49
:ANALysis:FFT<x>:MEASure:PEAK[:
Queries all settings related to the power value between peak values of the
:ANALysis:FFT<x>:MEASure:PEAK[:
Turns ON/OFF the power value between peak values of the FFT computation
or queries the current setting.
:ANALysis:FFT<x>:MEASure:PEAK[:
Queries the power value between peak values of the FFT computation.
:ANALysis:FFT<x>:MEASure:PEAK[:
Queries all settings related to the peak frequency value of the FFT
:ANALysis:FFT<x>:MEASure:PEAK[:
Turns ON/OFF the peak frequency value of the FFT computation or queries
:ANALysis:FFT<x>:MEASure:PEAK[:
Queries the peak frequency value of the FFT computation.
:ANALysis:FFT<x>:MEASure:PEAK[:
Sets the measurement range of the peak value of the FFT computation or
:ANALysis:FFT<x>:MEASure:PEAK[:
Queries all settings related to the peak value of the FFT computation.
:ANALysis:FFT<x>:MEASure:PEAK[:
Turns ON/OFF the peak value of the FFT computation or queries the current
:ANALysis:FFT<x>:MEASure:PEAK[:
Queries the peak value of the FFT computation.
:ANALysis:FFT<x>:MEASure:PEAK:
Queries all settings related to calculation items of the FFT computation.
:ANALysis:FFT<x>:MEASure:PEAK:
Turns ON/OFF all calculation items of the FFT computation.
:ANALysis:FFT<x>:MEASure:PEAK:
Sets the equation of the calculation item of the FFT computation or queries
:ANALysis:FFT<x>:MEASure:PEAK:
Turns ON/OFF the calculation items of the FFT computation or queries the
:ANALysis:FFT<x>:MEASure:PEAK:
Queries the measured value of the calculation item of the FFT computation. 5-51
Sets the measurement source window used in the FFT computation or
Sets the source trace of the real part of the FFT computation or queries the
:ANALysis:FFT<x>:RPOSition (Ref
Sets the center point of magnification of the vertical axis of the FFT
computation or queries the current setting.
Queries all settings related the vertical axis of the FFT computation.
:ANALysis:FFT<x>:VERTical:LEVel
Sets the display position of the vertical axis of the FFT computation or
:ANALysis:FFT<x>:VERTical:MODE
Sets the vertical axis mode of the FFT computation or queries the current
Sets the vertical sensitivity of the FFT computation or queries the current
Sets the window function of the FFT computation or queries the current
Sets the analysis function type or queries the current setting.
Turns ON/OFF the VT waveform display or queries the current setting.
Waits for the completion of the automated measurement with a timeout
Queries all settings related to the waveform parameter measurement
Sets the calculation items of the automated measurement of waveform
parameters or queries the current setting.
Queries all settings related to the histogram display of the waveform
Queries all settings related to the automated measurement of the histogram
display of the waveform parameter measurement.
Queries all settings related to the cursor measurement on the histogram of
the waveform parameter measurement.
Turns ON/OFF all histogram cursors of waveform parameter measurement. 5-54
5.1 List of Commands