5-167
IM 701310-17E
Commands
1
2
3
4
5
6
App
Index
:TRIGger:EINTerval:EVENt<x>:I2CBus:
GCALl:BIT7maddress?
Function Queries all settings related to the 7-bit master
address of the general call of the I
2
C bus trigger.
Syntax
:TRIGger:EINTerval:EVENt<x>:I2CBus:
GCALl:BIT7maddress?
<x> = 1 or 2
Example
:TRIGGER:EINTERVAL:EVENT1:I2CBUS:GCALL:
BIT7MADDRESS? -> :TRIGGER:EINTERVAL:
EVENT1:I2CBUS:GCALL:BIT7MADDRESS:
PATTERN "1010101"
:TRIGger:EINTerval:EVENt<x>:I2CBus:
GCALl:BIT7maddress:HEXA
Function Sets the 7-bit master address of the general call of
the I
2
C bus trigger in hexadecimal notation.
Syntax
:TRIGger:EINTerval:EVENt<x>:I2CBus:
GCALl:BIT7maddress:HEXA {<String>}
<x> = 1 or 2
<String> = 2 characters by combining ‘0’ to ‘F’ and ‘X’
(bit 0 is fixed 1)
Example
:TRIGGER:EINTERVAL:EVENT1:I2CBUS:GCALL:
BIT7MADDRESS:HEXA "AB"
:TRIGger:EINTerval:EVENt<x>:I2CBus:
GCALl:BIT7maddress:PATTern
Function Sets the 7-bit master address of the general call of
the I
2
C bus trigger in binary notation or queries the
current setting.
Syntax
:TRIGger:EINTerval:EVENt<x>:I2CBus:
GCALl:BIT7maddress:PATTern {<String>}
:TRIGger:EINTerval:EVENt<x>:I2CBus:
GCALl:BIT7maddress:PATTern?
<x> = 1 or 2
<String> = 7 characters by combining ‘0,’ ‘1,’ and ‘X’
Example
:TRIGGER:EINTERVAL:EVENT1:I2CBUS:GCALL:
BIT7MADDRESS:PATTERN "1010101"
:TRIGGER:EINTERVAL:EVENT1:I2CBUS:GCALL:
BIT7MADDRESS:PATTERN? -> :TRIGGER:
EINTERVAL:EVENT1:I2CBUS:GCALL:
BIT7MADDRESS:PATTERN "1010101"
:TRIGger:EINTerval:EVENt<x>:I2CBus:
GCALl:SBYTe (Second Byte)
Function Sets the second byte type of the general call of the
I
2
C bus trigger or queries the current setting.
Syntax
:TRIGger:EINTerval:EVENt<x>:I2CBus:
GCALl:SBYTe {BIT7maddress|DONTcare|H04|
H06}
:TRIGger:EINTerval:EVENt<x>:I2CBus:
GCALl:SBYTe?
<x> = 1 or 2
Example
:TRIGGER:EINTERVAL:EVENT1:I2CBUS:GCALL:
SBYTE BIT7MADDRESS
:TRIGGER:EINTERVAL:EVENT1:I2CBUS:GCALL:
SBYTE? -> :TRIGGER:EINTERVAL:EVENT1:
I2CBUS:GCALL:SBYTE BIT7MADDRESS
:TRIGger:EINTerval:EVENt<x>:I2CBus:
MODE
Function Sets the trigger mode of the I
2
C bus trigger or queries
the current setting.
Syntax
:TRIGger:EINTerval:EVENt<x>:I2CBus:
MODE {ADATa|ESTart|GCALl|NAIGnore|
SBHSmode}
:TRIGger:EINTerval:EVENt<x>:I2CBus:
MODE?
<x> = 1 or 2
Example
:TRIGGER:EINTERVAL:EVENT1:I2CBUS:
MODE ADATA
:TRIGGER:EINTERVAL:EVENT1:I2CBUS:MODE?
-> :TRIGGER:EINTERVAL:EVENT1:I2CBUS:
MODE ADATA
:TRIGger:EINTerval:EVENt<x>:I2CBus:
NAIGnore?
Function Queries all settings related to the NON ACK ignore
mode of the I
2
C bus trigger.
Syntax
:TRIGger:EINTerval:EVENt<x>:I2CBus:
NAIGnore?
<x> = 1 or 2
Example
:TRIGGER:EINTERVAL:EVENT1:I2CBUS:
NAIGNORE? -> :TRIGGER:EINTERVAL:EVENT1:
I2CBUS:NAIGNORE:HSMODE 1;RACCESS 1;
SBYTE 1
5.29 TRIGger Group