5-154
IM 701310-17E
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:DATA<x>
Function Sets the comparison data of the CAN bus signal
trigger data or queries the current setting.
Syntax
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:DATA<x> {<NRf>}
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:DATA<x>?
<x> of EVENt<x> = 1 or 2
<x> of DATA<x> = 1 or 2
<NRf> = See the User's Manual (IM701310-01E).
Example
:TRIGGER:EINTERVAL:EVENT1:CANBUS:
DATA:DATA1 1
:TRIGGER:EINTERVAL:EVENT1:CANBUS:
DATA:DATA1? -> :TRIGGER:EINTERVAL:
EVENT1:CANBUS:DATA:
DATA1 1.000
Description • Use
:TRIGger:EINTerval:EVENt<x>:
CANBus:DATA:DATA1
when
:TRIGger:
EINTerval:EVENt<x>:CANBus:DATA:
CONDition GTHan
is specified.
• Use
:TRIGger:EINTerval:EVENt<x>:
CANBus:DATA:DATA2
when
:TRIGger:
EINTerval:EVENt<x>:CANBus:DATA:
CONDition LTHan
is specified.
• Use
:TRIGger:EINTerval:EVENt<x>:
CANBus:DATA:DATA1
to set the smaller value
and
:TRIGger:EINTerval:EVENt<x>:
CANBus:DATA:DATA2
to set the larger value
when
:TRIGger:EINTerval:EVENt<x>:
CANBus:DATA:CONDition BETWeen|ORANge
is specified.
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:DLC
Function Sets the number of valid bytes (DLC) of the CAN bus
signal trigger data or queries the current setting.
Syntax
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:DLC {<NRf>}
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:DLC?
<x> = 1 or 2
<NRf> = 0 to 8
Example
:TRIGGER:EINTERVAL:EVENT1:CANBUS:
DATA:DLC 0
:TRIGGER:EINTERVAL:EVENT1:CANBUS:
DATA:DLC? -> :TRIGGER:EINTERVAL:
EVENT1:CANBUS:DATA:DLC 0
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:HEXA
Function Sets the CAN bus signal trigger data in hexadecimal
notation.
Syntax
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:HEXA {<String>}
<x> = 1 or 2
<String> = Up to 16 characters by combining ‘0’ to ‘F’
and ‘X’ (in one-byte unit)
Example
:TRIGGER:EINTERVAL:EVENT1:CANBUS:
DATA:HEXA "A9"
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:MSBLsb
Function Sets the MSB and LSB bits of the CAN bus signal
trigger data or queries the current setting.
Syntax
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:MSBLsb {<NRf>,<NRf>}
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:MSBLsb?
<x> = 1 or 2
<NRf> = See the User's Manual
(IM701310-01E).
Example
:TRIGGER:EINTERVAL:EVENT1:CANBUS:
DATA:MSBLSB 1,0
:TRIGGER:EINTERVAL:EVENT1:CANBUS:
DATA:MSBLSB? -> :TRIGGER:EINTERVAL:
EVENT1:CANBUS:DATA:MSBLSB 1,0
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:PATTern
Function Sets the CAN bus signal trigger data in binary
notation or queries the current setting.
Syntax
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:PATTern {<String>}
:TRIGger:EINTerval:EVENt<x>:CANBus:
DATA:PATTern?
<x> = 1 or 2
<String> = Up to 64 characters by
combining ‘0,’ ‘1,’ and ‘X’ (in one-byte unit)
Example
:TRIGGER:EINTERVAL:EVENT1:CANBUS:
DATA:PATTERN "11011111"
:TRIGGER:EINTERVAL:EVENT1:CANBUS:
DATA:PATTERN? -> :TRIGGER:EINTERVAL:
EVENT1:CANBUS:DATA:PATTERN "11011111"
5.29 TRIGger Group