5-187
IM 701310-17E
Commands
1
2
3
4
5
6
App
Index
:TRIGger:ENHanced:I2CBus:DATA:
DPOSition
Function Sets the position for comparing the data pattern of
the I
2
C bus trigger or queries the current setting.
Syntax
:TRIGger:ENHanced:I2CBus:DATA:
DPOSition {<NRf>}
:TRIGger:ENHanced:I2CBus:DATA:
DPOSition?
<NRf> = 0 to 9999
Example
:TRIGGER:ENHANCED:I2CBUS:DATA:
DPOSITION 1
:TRIGGER:ENHANCED:I2CBUS:DATA:
DPOSITION? -> :TRIGGER:ENHANCED:I2CBUS:
DATA:DPOSITION 1
:TRIGger:ENHanced:I2CBus:DATA:HEXA<x>
Function Sets the data of the I
2
C bus trigger in hexadecimal
notation.
Syntax
:TRIGger:ENHanced:I2CBus:DATA:
HEXA<x> {<String>}
<x> = 1 to 4
<String> = 2 characters by combining ‘0’ to ‘F’ and ‘X’
Example
:TRIGGER:ENHANCED:I2CBUS:DATA:
HEXA1 "AB"
:TRIGger:ENHanced:I2CBus:DATA:MODE
Function Enables/Disables the data conditions of the I
2
C bus
trigger or queries the current setting.
Syntax
:TRIGger:ENHanced:I2CBus:DATA:
MODE {<Boolean>}
:TRIGger:ENHanced:I2CBus:DATA:MODE?
Example
:TRIGGER:ENHANCED:I2CBUS:DATA:MODE ON
:TRIGGER:ENHANCED:I2CBUS:DATA:MODE?
-> :TRIGGER:ENHANCED:I2CBUS:DATA:MODE 1
:TRIGger:ENHanced:I2CBus:DATA:
PATTern<x>
Function Sets the data of the I
2
C bus trigger in binary notation
or queries the current setting.
Syntax
:TRIGger:ENHanced:I2CBus:DATA:
PATTern<x> {<String>}
:TRIGger:ENHanced:I2CBus:DATA:
PATTern<x>?
<x> = 1 to 4
<String> = 8 characters by combining ‘0,’ ‘1,’ and ‘X’
Example
:TRIGGER:ENHANCED:I2CBUS:DATA:
PATTERN1 "10101011"
:TRIGGER:ENHANCED:I2CBUS:DATA:PATTERN1?
-> :TRIGGER:ENHANCED:I2CBUS:DATA:
PATTERN1 "10101011"
:TRIGger:ENHanced:I2CBus:DATA:PMODe
Function Sets the pattern comparison start position mode of
the data of the I
2
C bus trigger or queries the current
setting.
Syntax
:TRIGger:ENHanced:I2CBus:DATA:
PMODe {DONTcare|SELect}
:TRIGger:ENHanced:I2CBus:DATA:PMODe?
Example
:TRIGGER:ENHANCED:I2CBUS:DATA:
PMODE SELECT
:TRIGGER:ENHANCED:I2CBUS:DATA:PMODE?
-> :TRIGGER:ENHANCED:I2CBUS:DATA:
PMODE SELECT
:TRIGger:ENHanced:I2CBus:DATA:SOURce
Function Sets the data trace of the I
2
C bus trigger or queries
the current setting.
Syntax
:TRIGger:ENHanced:I2CBus:DATA:
SOURce {<NRf>}
:TRIGger:ENHanced:I2CBus:DATA:SOURce?
<NRf> = 1 to 4
Example
:TRIGGER:ENHANCED:I2CBUS:DATA:SOURCE 1
:TRIGGER:ENHANCED:I2CBUS:DATA:SOURCE?
-> :TRIGGER:ENHANCED:I2CBUS:DATA:
SOURCE 1
:TRIGger:ENHanced:I2CBus:GCALl?
Function Queries all settings related to the general call of the
I
2
C bus trigger.
Syntax
:TRIGger:ENHanced:I2CBus:GCALl?
<x> = 1 or 2
Example
:TRIGGER:ENHANCED:I2CBUS:GCALL?
-> :TRIGGER:ENHANCED:I2CBUS:GCALL:
BIT7MADDRESS:PATTERN "1010101";:
TRIGGER:ENHANCED:I2CBUS:GCALL:
SBYTE BIT7MADDRESS
:TRIGger:ENHanced:I2CBus:GCALl:
BIT7maddress?
Function Queries all settings related to the 7-bit master
address of the general call of the I
2
C bus trigger.
Syntax
:TRIGger:ENHanced:I2CBus:GCALl:
BIT7maddress?
<x> = 1 or 2
Example
:TRIGGER:ENHANCED:I2CBUS:GCALL:
BIT7MADDRESS? -> :TRIGGER:ENHANCED:
I2CBUS:GCALL:BIT7MADDRESS:
PATTERN "1010101"
5.29 TRIGger Group