5-145
IM 701310-17E
Commands
1
2
3
4
5
6
App
Index
:TELecomtest:MASK:ELEMent<x>:
PSPCount? (Sample Point Count %)
Function Queries the settings related to the error rate for the
number of sampled data points of the element.
Syntax
:TELecomtest:MASK:ELEMent<x>:PSPCount?
<x> = 1 to 4
Example
:TELECOMTEST:MASK:ELEMENT1:PSPCOUNT?
-> :TELECOMTEST:MASK:ELEMENT1:PSPCOUNT:
STATE 1
:TELecomtest:MASK:ELEMent<x>:
PSPCount:STATe
Function Turns ON/OFF the measurement of the error rate for
the number of sampled data points of the element or
queries the current setting.
Syntax
:TELecomtest:MASK:ELEMent<x>:PSPCount:
STATe {<Boolean>}
:TELecomtest:MASK:ELEMent<x>:PSPCount:
STATe?
<x> = 1 to 4
Example
:TELECOMTEST:MASK:ELEMENT1:PSPCOUNT:
STATE ON
:TELECOMTEST:MASK:ELEMENT1:PSPCOUNT:
STATE? -> :TELECOMTEST:MASK:ELEMENT1:
PSPCOUNT:STATE 1
:TELecomtest:MASK:ELEMent<x>:
PSPCount:VALue?
Function Queries the error rate for the number of sampled data
points of the element.
Syntax
:TELecomtest:MASK:ELEMent<x>:PSPCount:
VALue?
<x> = 1 to 4
Example
:TELECOMTEST:MASK:ELEMENT1:PSPCOUNT:
VALUE? -> :TELECOMTEST:MASK:ELEMENT1:
PSPCOUNT:VALUE 1.000E+00
:TELecomtest:MASK:ELEMent<x>:
PWCount? (Wave Count %)
Function Queries the settings related to the error rate for the
acquisition count of the element.
Syntax
:TELecomtest:MASK:ELEMent<x>:PWCount?
<x> = 1 to 4
Example
:TELECOMTEST:MASK:ELEMENT1:PWCOUNT?
-> :TELECOMTEST:MASK:ELEMENT1:PWCOUNT:
STATE 1
:TELecomtest:MASK?
Function Queries all settings related to the mask test.
Syntax
:TELecomtest:MASK?
Example
:TELECOMTEST:MASK? -> :TELECOMTEST:
MASK:ELEMENT1:PSPCOUNT:STATE 1;:
TELECOMTEST:MASK:ELEMENT1:PWCOUNT:
STATE 1;:TELECOMTEST:MASK:ELEMENT1:
SPCOUNT:STATE 1;:TELECOMTEST:MASK:
ELEMENT1:WCOUNT:STATE 1;:TELECOMTEST:
MASK:ELEMENT2:PSPCOUNT:STATE 1;:
TELECOMTEST:MASK:ELEMENT2:PWCOUNT:
STATE 1;:TELECOMTEST:MASK:ELEMENT2:
SPCOUNT:STATE 1;:TELECOMTEST:MASK:
ELEMENT2:WCOUNT:STATE 1;:TELECOMTEST:
MASK:ELEMENT3:PSPCOUNT:STATE 1;:
TELECOMTEST:MASK:ELEMENT3:PWCOUNT:
STATE 1;:TELECOMTEST:MASK:ELEMENT3:
SPCOUNT:STATE 1;:TELECOMTEST:MASK:
ELEMENT3:WCOUNT:STATE 1;:TELECOMTEST:
MASK:ELEMENT4:PSPCOUNT:STATE 1;:
TELECOMTEST:MASK:ELEMENT4:PWCOUNT:
STATE 1;:TELECOMTEST:MASK:ELEMENT4:
SPCOUNT:STATE 1;:TELECOMTEST:MASK:
ELEMENT4:WCOUNT:STATE 1
:TELecomtest:MASK:ELEMent<x>?
Function Queries all settings related to the element used in the
mask test.
Syntax
:TELecomtest:MASK:ELEMent<x>?
<x> = 1 to 4
Example
:TELECOMTEST:MASK:ELEMENT1?
-> :TELECOMTEST:MASK:ELEMENT1:PSPCOUNT:
STATE 1;:TELECOMTEST:MASK:ELEMENT1:
PWCOUNT:STATE 1;:TELECOMTEST:MASK:
ELEMENT1:SPCOUNT:STATE 1;:TELECOMTEST:
MASK:ELEMENT1:WCOUNT:STATE 1
:TELecomtest:MASK:ELEMent<x>:ALL
Function Turns ON/OFF all items of the element.
Syntax
:TELecomtest:MASK:ELEMent<x>:ALL
{<Boolean>}
<x> = 1 to 4
Example
:TELECOMTEST:MASK:ELEMENT1:ALL ON
5.27 TELecomtest Group