5-171
IM 701310-17E
Commands
1
2
3
4
5
6
App
Index
:TRIGger:EINTerval:EVENt<x>:SPATtern:
LATCh:POLarity
Function Sets the polarity of the latch trace of the serial pattern
trigger or queries the current setting.
Syntax
:TRIGger:EINTerval:EVENt<x>:SPATtern:
LATCh:POLarity {FALL|RISE}
:TRIGger:EINTerval:EVENt<x>:SPATtern:
LATCh:POLarity?
<x> = 1 or 2
Example
:TRIGGER:EINTERVAL:EVENT1:SPATTERN:
LATCH:POLARITY FALL
:TRIGGER:EINTERVAL:EVENT1:SPATTERN:
LATCH:POLARITY? -> :TRIGGER:EINTERVAL:
EVENT1:SPATTERN:LATCH:POLARITY FALL
Description • This command is valid when
:TRIGger:
EINTerval:EVENt<x>:SPATtern:
CLOCk:MODE ON
.
• This command in invalid if
:TRIGger:
EINTerval:EVENt<x>:SPATtern:
LATCh:SOURce NONE
.
:TRIGger:EINTerval:EVENt<x>:SPATtern:
LATCh:SOURce
Function Sets the latch trace of the serial pattern trigger or
queries the current setting.
Syntax
:TRIGger:EINTerval:EVENt<x>:SPATtern:
LATCh:SOURce {<NRf>|NONE}
:TRIGger:EINTerval:EVENt<x>:SPATtern:
LATCh:SOURce?
<x> = 1 or 2
<NRf> = 1 to 4
Example
:TRIGGER:EINTERVAL:EVENT1:SPATTERN:
LATCH:SOURCE 1
:TRIGGER:EINTERVAL:EVENT1:SPATTERN:
LATCH:SOURCE? -> :TRIGGER:EINTERVAL:
EVENT1:SPATTERN:LATCH:SOURCE 1
Description This command is valid when
:TRIGger:
EINTerval:EVENt<x>:SPATtern:CLOCk:
MODE ON
.
:TRIGger:EINTerval:EVENt<x>:SPATtern:
PATTern
Function Sets the pattern of the serial pattern trigger in binary
notation or queries the current setting.
Syntax
:TRIGger:EINTerval:EVENt<x>:SPATtern:
PATTern {<String>}
:TRIGger:EINTerval:EVENt<x>:SPATtern:
PATTern?
<x> = 1 or 2
<String> = Up to 128 characters by combining ‘0’, ‘1’,
and ‘X’
Example
:TRIGGER:EINTERVAL:EVENT1:SPATTERN:
PATTERN "1100110111101111"
:TRIGGER:EINTERVAL:EVENT1:SPATTERN:
PATTERN? -> :TRIGGER:EINTERVAL:EVENT1:
SPATTERN:PATTERN "1100110111101111"
:TRIGger:EINTerval:EVENt<x>:SPIBus?
Function Queries all settings related to the SPI bus trigger of
the event.
Syntax
:TRIGger:EINTerval:EVENt<x>:SPIBus?
<x> = 1 or 2
Example
:TRIGGER:EINTERVAL:EVENT1:SPIBUS?
-> :TRIGGER:EINTERVAL:EVENT1:SPIBUS:
BITORDER LSBFIRST;CLOCK:POLARITY FALL;
SOURCE 1;:TRIGGER:EINTERVAL:EVENT1:
SPIBUS:CS:ACTIVE HIGH;SOURCE 1;:
TRIGGER:EINTERVAL:EVENT1:SPIBUS:DATA1:
BYTE 1;CONDITION TRUE;DPOSITION 1;
PATTERN1 "00010010";
PATTERN2 "00110100";
PATTERN3 "01010110";
PATTERN4 "00010010";SOURCE 3;:TRIGGER:
EINTERVAL:EVENT1:SPIBUS:DATA2:BYTE 4;
CONDITION TRUE;DPOSITION 1;
PATTERN1 "00010010";
PATTERN2 "00110100";
PATTERN3 "01010110";
PATTERN4 "00010010";SOURCE 3;:TRIGGER:
EINTERVAL:EVENT1:SPIBUS:MODE WIRE3
:TRIGger:EINTerval:EVENt<x>:SPIBus:
BITorder
Function Sets the bit order of the SPI bus trigger or queries the
current setting.
Syntax
:TRIGger:EINTerval:EVENt<x>:SPIBus:
BITorder {LSBFirst|MSBFirst}
:TRIGger:EINTerval:EVENt<x>:SPIBus:
BITorder?
<x> = 1 or 2
Example
:TRIGGER:EINTERVAL:EVENT1:SPIBUS:
BITORDER LSBFIRST
:TRIGGER:EINTERVAL:EVENT1:SPIBUS:
BITORDER? -> :TRIGGER:EINTERVAL:
EVENT1:SPIBUS:BITORDER LSBFIRST
5.29 TRIGger Group