5-186
IM 701310-17E
:TRIGger:ENHanced:I2CBus:CLOCk:SOURce
Function Sets the clock trace of the I
2
C bus trigger or queries
the current setting.
Syntax
:TRIGger:ENHanced:I2CBus:CLOCk:
SOURce {<NRf>}
:TRIGger:ENHanced:I2CBus:CLOCk:SOURce?
<NRf> = 1 to 4
Example
:TRIGGER:ENHANCED:I2CBUS:CLOCK:SOURCE 1
:TRIGGER:ENHANCED:I2CBUS:CLOCK:SOURCE?
-> :TRIGGER:ENHANCED:I2CBUS:CLOCK:
SOURCE 1
:TRIGger:ENHanced:I2CBus:DATA?
Function Queries all settings related to the data of the I
2
C bus
trigger.
Syntax
:TRIGger:ENHanced:I2CBus:DATA?
<x> = 1 or 2
Example
:TRIGGER:ENHANCED:I2CBUS:DATA?
-> :TRIGGER:ENHANCED:I2CBUS:DATA:BYTE 1;
CONDITION TRUE;DPOSITION 1;MODE 1;
PATTERN1 "10101011";
PATTERN2 "10101010";
PATTERN3 "10101111";
PATTERN4 "10101011";PMODE DONTCARE;
SOURCE 1
:TRIGger:ENHanced:I2CBus:DATA:BYTE
Function Sets the number of data bytes of the I
2
C bus trigger
or queries the current setting.
Syntax
:TRIGger:ENHanced:I2CBus:DATA:
BYTE {<NRf>}
:TRIGger:ENHanced:I2CBus:DATA:BYTE?
<NRf> = 1 to 4
Example
:TRIGGER:ENHANCED:I2CBUS:DATA:BYTE 1
:TRIGGER:ENHANCED:I2CBUS:DATA:BYTE?
-> :TRIGGER:ENHANCED:I2CBUS:DATA:BYTE 1
:TRIGger:ENHanced:I2CBus:DATA:
CONDition
Function Sets the determination method (match or not match)
of the data of the I
2
C bus trigger or queries the
current setting.
Syntax
:TRIGger:ENHanced:I2CBus:DATA:
CONDition {FALSe|TRUE}
:TRIGger:ENHanced:I2CBus:DATA:
CONDition?
Example
:TRIGGER:ENHANCED:I2CBUS:DATA:
CONDITION TRUE
:TRIGGER:ENHANCED:I2CBUS:DATA:
CONDITION? -> :TRIGGER:ENHANCED:I2CBUS:
DATA:CONDITION TRUE
:TRIGger:ENHanced:I2CBus:ADATa:
BIT7APsub:SADDress:HEXA
Function Sets the Sub address of the 7-bit + Sub address of
the I
2
C bus trigger in hexadecimal notation.
Syntax
:TRIGger:ENHanced:I2CBus:ADATa:
BIT7APsub:SADDress:HEXA {<String>}
<String> = 2 characters by combining ‘0’ to ‘F’ and ‘X’
Example
:TRIGGER:ENHANCED:I2CBUS:ADATA:
BIT7APSUB:SADDRESS:HEXA "EF"
:TRIGger:ENHanced:I2CBus:ADATa:
BIT7APsub:SADDress:PATTern
Function Sets the Sub address of the 7-bit + Sub address of
the I
2
C bus trigger in binary notation or queries the
current setting.
Syntax
:TRIGger:ENHanced:I2CBus:ADATa:
BIT7APsub:SADDress:PATTern {<String>}
:TRIGger:ENHanced:I2CBus:ADATa:
BIT7APsub:SADDress:PATTern?
<String> = 8 characters by combining ‘0,’ ‘1,’ and ‘X’
Example
:TRIGGER:ENHANCED:I2CBUS:ADATA:
BIT7APSUB:SADDRESS:PATTERN "10101011"
:TRIGGER:ENHANCED:I2CBUS:ADATA:
BIT7APSUB:SADDRESS:PATTERN? -> :
TRIGGER:ENHANCED:I2CBUS:ADATA:
BIT7APSUB:SADDRESS:PATTERN "10101011"
:TRIGger:ENHanced:I2CBus:ADATa:TYPE
Function Sets the address type of the I
2
C bus trigger or queries
the current setting.
Syntax
:TRIGger:ENHanced:I2CBus:ADATa:
TYPE {BIT10address|BIT7ADdress|
BIT7APsub}
:TRIGger:ENHanced:I2CBus:ADATa:TYPE?
Example
:TRIGGER:ENHANCED:I2CBUS:ADATA:
TYPE BIT10ADDRESS
:TRIGGER:ENHANCED:I2CBUS:ADATA:TYPE?
-> :TRIGGER:ENHANCED:I2CBUS:ADATA:
TYPE BIT10ADDRESS
:TRIGger:ENHanced:I2CBus:CLOCk?
Function Queries all settings related to the clock of the I
2
C bus
trigger.
Syntax
:TRIGger:ENHanced:I2CBus:CLOCk?
Example
:TRIGGER:ENHANCED:I2CBUS:CLOCK?
-> :TRIGGER:ENHANCED:I2CBUS:CLOCK:
SOURCE 1
5.29 TRIGger Group