5-20
IM 701310-17E
Command
Function
Page
Sets the polarity of the clock channel or queries the current setting.
Sets the clock trace of the search or queries the current setting.
Sets the decimation detection of the skip mode or queries the current setting. 5-132
Executes the search. This is an overlap command.
Sets the hold off detection or queries the current setting.
Sets the search logic or queries the current setting.
Sets the search polarity or queries the current setting.
Sets the detection waveform number of the search function and queries the
position that corresponds to the detection waveform number.
Queries the detection count of the search function.
Sets the skip mode or queries the current setting.
Queries all settings related to the serial pattern search.
Queries all settings related to clock of the serial pattern search.
:SEARch<x>:SPATtern:CLOCk:MODE
Enables/Disables the clock of the serial pattern search or queries the current
Sets the polarity of the clock trace of the serial pattern search or queries the
Sets the clock trace of the serial pattern search or queries the current setting. 5-134
Enables/Disables the chip select of the serial pattern search or queries the
Queries all settings related to latch of the serial pattern search.
Sets the polarity of the latch trace of the serial pattern search or queries the
:SEARch<x>:SPATtern:LATCh:TRACe
Sets the latch trace of the serial pattern search or queries the current setting. 5-134
Queries all settings related to setup of the serial pattern search.
Sets the bit rate of the serial pattern search or queries the current setting.
Clears the entire pattern of the serial pattern search (to don’t care).
Queries all settings related to data of the serial pattern search.
Sets the active level of the data trace of the serial pattern search or queries
Sets the data trace of the serial pattern search or queries the current setting. 5-135
Sets the pattern of the serial pattern search in hexadecimal notation.
Sets the pattern of the serial pattern search in binary notation or queries the
Sets the search start position or queries the current setting.
Sets the search source trace or queries the current setting.
Queries all settings related to the search conditions of the trace.
Sets the condition to be satisfied for the trace or queries the current setting. 5-136
:SEARch<x>:TRACe<x>:HYSTeresis
Sets the hysteresis of the trace or queries the current setting.
Sets the threshold level of the trace or queries the current setting.
Sets the search type or queries the current setting.
Queries all settings related to the pulse width search.
Sets the pulse width determination mode or queries the current setting.
Sets the pulse width of the pulse width search or queries the current setting. 5-136
Sets the pulse width search type or queries the current setting.
Starts the waveform acquisition with the trigger mode set to single. If the
waveform acquisition stops within the specified time period, 0 is returned at
5.1 List of Commands