5-4
IM CA700-01EN
5.3 List of Commands
Item
Command Description
Normal
User
Adjustment
Data retrieval
OD
Requests to send measured data.
Yes
Yes
Measure and source MS
Sets or queries the measurement/source mode.
Yes
No
Measurement
function
MR
Sets or queries the measurement range.
Yes
No
HD
Holds or queries the measurement value display.
Yes
No
LT
Starts or stops a leak test.
Yes
No
PZ
Executes pressure zero calibration.
Yes
No
TO
Starts or stops data logging.
Yes
No
TS
Executes manual saving.
Yes
No
Source function
SD
Sets or queries the normal source value.
Yes
No
SO
Starts or stops or queries the source.
Yes
No
Adjustment
SY
Switches or queries the normal/adjustment mode.
Yes
Yes
CL
Sets or queries the adjustment item.
No
Yes
CP
Sets the adjustment point.
No
Yes
CMF
Sets or queries the adjustment measurement function.
No
Yes
CMR
Sets or queries the adjustment measurement range.
No
Yes
CS
Confirms measurement data during measurement adjustment.
No
Yes
CSF
Queries the adjustment source function.
No
Yes
CR
Sets or queries the source adjustment value.
No
Yes
CD
Sets the source value for adjustment.
No
Yes
CW
Writes adjustment data.
No
Yes
Source/
measurement
settings
MF
Sets or queries the normal measurement function.
Yes
No
SF
Sets or queries the source function.
Yes
No
LP
Sets or queries the leak test leak period.
Yes
No
PU
Sets or queries the pressure unit.
Yes
No
AG
Sets or queries averaging.
Yes
No
SC
Sets and queries the scaling.
Yes
No
SP
Sets and queries % span.
Yes
No
Device settings
AP
Sets or queries the auto power-off feature.
Yes
No
DT
Sets or queries the date/time.
Yes
Yes
LC
Sets or queries the LCD contrast.
Yes
No
LG
Sets or queries the language.
Yes
No
TD
Sets or queries the number of log points.
Yes
No
TM
Sets or queries the data save method.
Yes
No
TR
Sets or queries the logging interval.
Yes
No
IO
Sets or queries the on/off state of the 250 Ω internal resistor.
Yes
No
PD
Sets or queries the number of pressure display digits.
Yes
No
Other
OE
Outputs error information.
Yes
Yes
YC
Initializes measurement settings.
Yes
No
ESC S
Outputs the status byte.
Yes
Yes
H
Sets or queries the presence or absence of output data headers.
Yes
Yes
IM
Sets or queries the status byte mask.
Yes
Yes
BL
Sets or queries the on/off state of the backlight.
Yes
Yes
ZC
Initializes the zero calibration value.
Yes
No
XR
Queries the MAX range.
Yes
Yes
BSN
Queries the serial number.
Yes
Yes
BGD
Queries the calibration date.
Yes
Yes
FCN
Queries the connection state of the external pressure sensor.
Yes
Yes
FMN
Queries the model number of the external sensor.
Yes
Yes
FSN
Queries the serial number of the external sensor.
Yes
Yes
FGD
Queries the calibration date of the external sensor.
Yes
Yes
UD
Sets the user calibration date of the CA700.
Yes
Yes
RUD
Queries the user calibration date of the CA700.
Yes
Yes
EUD
Sets the user calibration date of the external pressure sensor.
Yes
Yes
REU
Queries the user calibration date of the external pressure sensor. Yes
Yes