![YASKAWA VIPA System SLIO Скачать руководство пользователя страница 162](http://html.mh-extra.com/html/yaskawa/vipa-system-slio/vipa-system-slio_manual_907132162.webp)
Local double word 8 of OB 40 at Alarm Inputs
Local byte
Bit 7...0
8
n
Bit 0: Edge at I+0.0
n
Bit 1: Edge at I+0.1
n
Bit 2: Edge at I+0.2
n
Bit 3: Edge at I+0.3
n
Bit 4: Edge at I+0.4
n
Bit 5: Edge at I+0.5
n
Bit 6: Edge at I+0.6
n
Bit 7: Edge at I+0.7
9
n
Bit 0: Edge at I+1.0
n
Bit 1: Edge at I+1.1
n
Bit 2: Edge at I+1.2
n
Bit 3: Edge at I+1.3
n
Bit 4: Edge at I+1.4
n
Bit 5: Edge at I+1.5
n
Bit 6: Edge at I+1.6
n
Bit 7: Edge at I+1.7
10...11
n
Bit 7 ... 0: 0 (fix)
Local double word 8 of OB 40 at counter function
Local byte
Bit 7...0
8
n
Bit 1, 0: 0 (fix)
n
Bit 2: Over-/underflow value counter 0
n
Bit 3: Counter 0 reached comparison value
n
Bit 7 ... 4: 0 (fix)
9
n
Bit 1, 0: 0 (fix)
n
Bit 2: Over-/underflow value counter 1
n
Bit 3: Counter 1 reached comparison value
n
Bit 7 ... 4: 0 (fix)
10
n
Bit 1, 0: 0 (fix)
n
Bit 2: Over-/underflow value counter 2
n
Bit 3: Counter 2 reached comparison value
n
Bit 7 ... 4: 0 (fix)
11
n
Bit 0: Gate counter 3 open (activated)
n
Bit 1: Gate counter 3 closed
n
Bit 2: Over-/underflow value counter 3
n
Bit 3: Counter 3 reached comparison value
n
Bit 4: Counter 3 new latch value
n
Bit 7 ... 5: 0 (fix)
VIPA System SLIO
Deployment I/O periphery
Diagnostic and interrupt > Process interrupt
HB300 | CPU | 013-CCF0R00 | en | 19-30
162