7.4 Cooling Fan and Circulation Fan
YASKAWA ELECTRIC
SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
319
P
e
ri
o
d
ic
In
sp
ect
ion &
Ma
in
te
na
nce
7
7.4
Cooling Fan and Circulation Fan
NOTICE: Follow cooling fan replacement instructions. The cooling fan cannot operate properly when installed incorrectly and could
seriously damage the drive. To ensure maximum useful product life, replace all cooling fans when performing maintenance.
Contact your Yaskawa representative or the nearest Yaskawa sales office to order replacement cooling fans or circulation
fans as required.
For drives with multiple cooling fans, replace all the fans when performing maintenance to ensure maximum product
performance life.
u
Number of Fans
Three-Phase 200 V Class
Three-Phase 400 V Class
Model
CIMR-T
Cooling Fan
Circulation Fan
Page
Model
CIMR-T
Cooling Fan
Circulation Fan
Page
2A0004
–
–
–
4A0002
–
–
–
2A0006
–
–
4A0004
–
–
2A0010
–
–
4A0005
–
–
2A0012
–
–
4A0007
1
–
2A0021
1
–
4A0009
1
–
2A0030
2
–
4A0011
1
–
2A0040
2
–
4A0018
2
–
2A0056
2
–
4A0023
2
–
2A0069
2
–
4A0031
2
–
2A0081
2
–
4A0038
2
–
2A0110
2
–
4A0044
2
–
2A0138
2
–
4A0058
2
–
2A0169
2
–
4A0072
2
–
2A0211
2
–
4A0088
2
–
2A0250
2
–
4A0103
2
–
2A0312
2
–
4A0139
2
–
2A0360
3
1
4A0165
2
–
2A0415
3
1
4A0208
2
–
4A0250
3
–
4A0296
3
–
4A0362
3
1
Содержание T1000A
Страница 4: ...4 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 32: ...1 5 Component Names 32 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 104: ...4 10 Test Run Checklist 104 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 334: ...7 5 Drive Replacement 334 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 362: ...A 6 Drive Derating Data 362 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...