2.2 Mechanical Installation
38
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
u
Digital Operator Remote Usage
n
Remote Operation
The digital operator mounted on the drive can be removed and connected to the drive using an extension cable up to 3 m
long. This makes it easier to operate the drive when it is installed in a location where it can not be accessed easily.
The digital operator can also be permanently mounted in a remote location like a panel door. An extension cable and an
installation support set (depending on the installation type) will be required.
Note:
Refer to Drive Options and Peripheral Devices on page 338
for information on extension cables and installation support sets.
Figure 2.5
Figure 2.4 Communication Cable Connection
n
Digital Operator Remote Installation
Digital Operator Dimensions
Figure 2.5 Digital Operator Dimensions
Installation Types and Required Materials
There are two ways the digital operator can be mounted to an enclosure:
1.
External/face-mount installs the operator outside the enclosure panel
2.
Internal/flush-mount installs the operator inside the enclosure panel
Table 2.2 Digital Operator Installation Methods and Required Tools
Installation Method
Description
Installation Support Sets
Model
Required Tools
External/Face-Mount
Simplified installation with the digital
operator is mounted on the outside of
the panel with two screws.
–
–
Phillips screwdriver (#1)
Internal/Flush-Mount
Encloses the digital operator in the
panel. The digital operator is flush
with the outside of the panel.
Installation Support Set A
(for mounting with screws through
holes in the panel)
EZZ020642A
Phillips screwdriver (#1, #2)
Installation Support Set B
(for use with threaded studs that are
fixed to the panel)
EZZ020642B
Phillips screwdriver (#1)
Wrench (7 mm)
S / N : J007XE273710001
Operator
Drive
Communication Cable Connector
Comm Port
common_
TMonly
S / N : J007XE273710001
90
78
60
7.9
minimum
50
Unit: mm
12.2
1.6
Installation holes (2-M3 screws, depth 5)
44
15
Содержание T1000A
Страница 4: ...4 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 32: ...1 5 Component Names 32 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 104: ...4 10 Test Run Checklist 104 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 334: ...7 5 Drive Replacement 334 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 362: ...A 6 Drive Derating Data 362 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...