352
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
A.1 Heavy Duty and Normal Duty Ratings
A.1
Heavy Duty and Normal Duty Ratings
The capacity of the drive is based on two types of load characteristics: Heavy Duty (HD) and Normal Duty (ND).
Refer to Selecting the Appropriate Load Rating on page 352
for the differences between HD and ND.
Table A.1 Selecting the Appropriate Load Rating
Note:
Differences between HD ratings and ND ratings for the drive include rated input and output current, overload capacity, carrier
frequency, and current limit. The default setting is for HD (C6-01 = 0).
Setting Parameter C6-01
<1> Refer to
Three-Phase 200 V Class Drives on page 353
Three-Phase 400 V Class Drives on page 354
for information on rating changes
based on drive model.
Rated Output Current
Overload Tolerance
Default Carrier Frequency
0: Heavy Duty (default)
HD Rating varies by model
150% rated output current for 60 s
2 kHz
1: Normal Duty
ND Rating varies by model
120% rated output current for 60 s varies by model
2 kHz
TERMS
TERMS
TERMS
HD and ND
: HD refers to applications requiring constant torque output, while ND refers to applications with variable torque
needs.
Содержание T1000A
Страница 4: ...4 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 32: ...1 5 Component Names 32 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 104: ...4 10 Test Run Checklist 104 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 334: ...7 5 Drive Replacement 334 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 362: ...A 6 Drive Derating Data 362 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...