70
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
3.12 Wiring Checklist
3.12 Wiring Checklist
No.
Item
Page
Drive, peripherals, option cards
1
Check drive model number to ensure receipt of correct model.
2
Make sure you have the correct braking resistors, DC reactors, noise filters, and other peripheral devices.
3
Check the option card model number.
Installation area and physical setup
4
Ensure that the area surrounding the drive complies with specifications.
Power supply voltage, output voltage
5
The voltage from the power supply should be within the input voltage specification range of the drive.
6
The voltage rating for the motor should match the drive output specifications.
7
Verify that the drive is properly sized to run the motor.
Main circuit wiring
8
Confirm proper branch circuit protection as specified by national and local codes.
9
Properly wire the power supply to drive terminals R/L1, S/L2, and T/L3.
10
Properly wire the drive and motor together.
The motor lines and drive output terminals R/T1, V/T2, and W/T3 should match in order to produce the desired phase order. If the phase order
is incorrect, the drive will rotate in the opposite direction.
11
Use 600 Vac vinyl-sheathed wire for the power supply and motor lines.
12
Use the correct wire gauges for the main circuit.
Refer to Wire Gauges and Tightening Torque on page 54
.
• When using comparatively long motor cable, calculate the amount of voltage drop.
• If the cable between the drive and motor exceeds 50 m, adjust the carrier frequency set to C6-02 accordingly.
13
Properly ground the drive. Review page
.
14
Tightly fasten all terminal screws (control circuit terminals, grounding terminals).
Refer to Wire Gauges and Tightening Torque on page 54
.
15
Set up overload protection circuits when running multiple motors from a single drive.
Note:
Close MC1 through MCn before operating the drive (MC1 through MCn cannot be switched off during run).
–
16
If using a braking resistor or dynamic braking resistor unit, install a magnetic contactor. Properly install the resistor, and ensure that overload
protection shuts off the power supply.
17
Verify phase advancing capacitors, input noise filters, or ground fault circuit interrupters are NOT installed on the output side of the drive.
–
Control circuit wiring
18
Use twisted-pair line for all drive control circuit wiring.
19
Ground the shields of shielded wiring to the ground terminal.
20
If using a 3-wire sequence, properly set parameters for multi-function contact input terminals S1 through S8, and properly wire control
circuits.
–
21
Properly wire any option cards.
22
Check for any other wiring mistakes.
Only use a multimeter to check wiring.
–
23
Properly fasten the control circuit terminal screws in the drive.
Refer to Wire Gauges and Tightening Torque on page 54
.
24
Pick up all wire clippings.
–
25
Ensure that no frayed wires on the terminal block are touching other terminals or connections.
–
26
Properly separate control circuit wiring and main circuit wiring.
–
27
Analog signal line wiring should not exceed 50 m.
–
28
Safe Disable input wiring should not exceed 30 m.
–
Motor rated voltage (V) x 0.02 ≥
3 x wire resistance (
Ω
/km) x cable length (m) x motor rated current (A) x 10
-3
M1
OL1
OL2
OLn
MC1
MC2
MCn
M2
Mn
Drive
MC1 - MCn
OL 1 - OL n
... magnetic contactor
... thermal relay
Power supply
Содержание T1000A
Страница 4: ...4 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 32: ...1 5 Component Names 32 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 104: ...4 10 Test Run Checklist 104 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 334: ...7 5 Drive Replacement 334 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 362: ...A 6 Drive Derating Data 362 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...