The following table of peripheral devices lists the names of the various accessories and options available for Yaskawa
drives. Contact Yaskawa or your Yaskawa agent to order these peripheral devices.
•
Peripheral Device Selection
: Refer to the Yaskawa catalog for selection and part numbers.
•
Peripheral Device Installation
: Refer to the corresponding option manual for installation instructions.
Table 8.1 Available Peripheral Devices
Option
Model Number
Description
Power Options
DC Reactor
-
Improves the power factor by suppressing harmonic distortion from the power
supply.
AC Reactor
-
Protects the drive when operating from a large power supply and improves the
power factor by suppressing harmonic distortion. Highly recommended for power
supplies that exceed 600 kVA.
Braking Resistor
ERF-150WJ Series
For use with systems that require dynamic braking with up to 3% ED. If higher
ED is required, increase the capacity.
Braking Resistor with Fuse
CF120-B579 Series
For use with systems that require dynamic braking with up to 3% ED. If higher
ED is required, increase the capacity.
Braking Unit
CDBR Series
External braking transistor
Input / Output Option Cards
Analog Input
AI-A3
Allows high precision, high resolution analog reference input.
Input channels: 3
Voltage input: -10 to 10 Vdc (20 k
Ω
), 13 bit signed
Current input: 4 to 20 mA or 0 to 20 mA (250 k
Ω
), 12 bit
Analog Monitor
AO-A3
Provides extra multi-function analog output terminals.
Output channels: 2
Output voltage: -10 to 10 V, 11 bit (signed)
Digital Input
DI-A3
Used to set the frequency reference by digital inputs
Input channels: 18 (including SET signal and SIGN signal)
Input signal type: BCD 16 bit (4 digit), 12 bit (3 digit), 8 bit (2 digit)
Input signal: 24 Vdc, 8 mA
Digital Output
DO-A3
Provides extra insulated multi-function digital outputs.
Photocoupler relays: 6 (48 V, up to 50 mA)
Contact relays: 2 (250 Vac/up to 1 A, 30 Vdc/up to 1 A)
Motor Speed Feedback Option Cards
Complementary PG
PG-B3
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or two tracks), for HTL encoder connection,
50 kHz max
Output: 3 track, open collector
Encoder power supply: 12 V, max current 200 mA
Line Driver PG
PG-X3
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or two tracks), line driver, 300 kHz max
Output: 3 track, line driver
Encoder power supply: 5 V or 12 V, max current 200 mA
Communication Options Cards
MECHATROLINK-II
SI-T3
Connects to a MECHATROLINK-II network
Interface Options
LCD Operator
JVOP-180
Digital operator with 8 languages, clear text LCD display, and copy function;
max. cable length for remote usage: 3 m
LED Operator
JVOP-182
5-digits LED operator; max. cable length for remote usage: 3 m
Remote Operator Cable
WV001/WV003
Extension cable (1 m or 3 m) to connect the digital operator for remote operation
RJ-45, 8 pin straight through, UTP CAT5e cable
USB Copy Unit
JVOP-181
Allows the user to copy and verify parameter settings between drives. Can also be
used as an adapter to connect the drive to the USB port on a PC.
Mechanical Options
Attachment for External Heatsink
EZZ02800A/B/C/D
Installation kit for mounting the drive with the heatsink outside of the panel (Side-
by-Side mounting possible)
NEMA 1 Kit
EZZ020787
Parts to make the drive conform to NEMA Type 1 enclosure requirements
Installation Support Set A
EZZ020642A
For installing the digital operator keypad on the outside of an enclosure panel that
houses the drive. Also refer to
Digital Operator Remote Installation on page 38
.
Installation Support Set B
EZZ020642B
Others
24 V Power Supply
200 V class: PS-A10L
400 V class: PS-A10H
Provides power to the control circuit and option boards in the event of power loss.
Allows the user to still monitor drive settings and fault information even if the
main circuit has no power.
PC Software Tools
DriveWizard Plus
-
PC tool for drive setup and parameter management
Содержание T1000A
Страница 4: ...4 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 32: ...1 5 Component Names 32 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 104: ...4 10 Test Run Checklist 104 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 334: ...7 5 Drive Replacement 334 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 362: ...A 6 Drive Derating Data 362 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...