5.6 Internal Set Speed Control
5-53
5
Ope
rat
ion
5.6
Internal Set Speed Control
This section describes operation using speed control with the internal set speeds.
This function enables an operation to be executed at a controlled speed. The speed, direction, or both are
selected in accordance with a combination of input signals from an external source. Servomotor speed settings
are made beforehand using the parameters in the SERVOPACK. Because the speed is controlled with a param-
eter in the SERVOPACK, an external pulse generator or a reference generator that controls speed is not
needed.
∗
When using the external input signal pins as factory settings, the functions of /P-CON, /P-CL, and /N-CL change to the
functions of /SPD-D, /SPD-A, and /SPD-B, respectively.
5.6.1
Basic Settings for Speed Control with an Internal Set Speed
This section describes the basic settings for the internal set speeds.
(1) Signal Setting
The following input signals are used to switch the operating speed.
Factory-set Input Signal Allocations: /P-CON, /P-CL, and /N-CL
Changing Input Signal Allocations: /SPD-D, /SPD-A, and /SPD-B
(2) Parameter Setting
Select the speed control with an internal set speed with Pn000.1.
41
45
46
Pn301
Pn302
Pn303
M
/ P-CON ( / SPD-D)
/ P-CL (
/ SPD-A)
/ N-CL (
/ SPD-B)
CN1
Stops (Internal speed 0)
SERVOPACK
Parameters for internal set speed
Motor rotation direction
(Forward/Reverse)
Speed
reference
Servomotor
Contact inputs*
Analog
Type
Signal
Name
Connector
Pin Number
Meaning
Input
/P-CON
CN1-41
Switches the servomotor rotation direction.
/P-CL
CN1-45
Selects the internal set speed.
/N-CL
CN1-46
Selects the internal set speed.
Type
Signal
Name
Connector
Pin Number
Meaning
Input
/SPD-D
CN1-41
Switches the servomotor rotation direction.
/SPD-A
CN1-45
Selects the internal set speed.
/SPD-B
CN1-46
Selects the internal set speed.
Parameter
Meaning
When Enabled Classification
Pn000
n.
3
Internal set speed control
After restart
Setup