9.1 System Configuration and Connection Example for SERVOPACK with Fully-closed Loop Control
9-7
9
Fu
lly-close
d L
oop
Co
ntro
l
9.1.6
Precautions When Using an External Incremental Encoder by Magnescale
When an external incremental encoder by Magnescale Co., Ltd. is used, the count direction of the encoder
determines if a phase-C pulse (CN1-19, CN1-20) is output and counted.
Note: The count direction (counting up or down) of the encoder determines if a phase-C pulse is output. The output of the
pulse does not depend on the settings of these parameters: Pn000.0 (motor rotational direction ) and Pn002.3 (exter-
nal encoder usage method).
When Passing 1st
Zero Point in Forward Direction and Returning after Power ON
After the power is turned on, the phase-C pulse (CN1-19, CN1-20) is output when the external encoder moves
forward and its detection head first passes the phase-C detection position. After the detection head of the
encoder passes the detection position in a forward direction, the phase-C pulse is output when the head passes
the position regardless of the direction of the encoder’s movement.
Model
Interpolator
Scale pitch (
μ
m)
SL710
PL101-RY
800
SL720
800
SL730
800
SR75
80
SR85
80
Scale count-up direction
Phase-C detection position
Power ON
Time
Phase-C pulse output
The phase-C pulse is also output when the detection head of the encoder passes
this point in reverse, because the SERVOPACK has recorded the position
where the phase-C pulse was originally output when first passing the position in the forward direction.
Rotation