11.2 List of Parameters
11-33
11
Ap
pend
ix
Pn522
4
Positioning Completed Width
0 to
1073741824
1
reference
unit
7
Immediately
Setup
5.4.6
Pn524
4
NEAR Signal Width
1 to
1073741824
1
reference
unit
1073741824
Immediately
Setup
5.4.7
Pn526
4
Excessive Position Error Alarm
Level at Servo ON
1 to
1073741823
1
reference
unit
5242880
Immediately
Setup
6.1.4
Pn528
2
Excessive Position Error Warn-
ing Level at Servo ON
10 to 100
1%
100
Immediately
Setup
6.1.4
Pn529
2
Speed Limit Level at Servo ON
0 to 10000
1 min
-1
10000
Immediately
Setup
6.1.4
Pn52A
2
Multiplier per One
Fully-closed Rotation
0 to 100
1%
20
Immediately
Tuning
9.3.6
Pn52B
2
Overload Warning Level
1 to 100
1%
20
Immediately
Setup
5.2.8
Pn52C
2
Derating of Base Current at
Detecting Overload of Motor
10 to 100
1%
100
After restart
Setup
5.2.8
Pn52D
2
Reserved (Do not change.)
–
–
50
–
–
–
Pn52F
2
Monitor Display at Power ON
0000 to 0FFF
−
0FFF
Immediately
Setup
8.7
Pn530
2
Program JOG Operation Related
Switch
0000 to 0005
−
0000
Immediately
Setup
7.5
Pn531
4
Program JOG Movement
Distance
1 to
1073741824
1
reference
unit
32768
Immediately
Setup
7.5
Pn533
2
Program JOG Movement Speed
1 to 10000
1 min
-1
500
Immediately
Setup
7.5
Pn534
2
Program JOG Acceleration/
Deceleration Time
2 to 10000
1 ms
100
Immediately
Setup
7.5
Pn535
2
Program JOG Waiting Time
0 to 10000
1 ms
100
Immediately
Setup
7.5
Pn536
2
Number of Times of Program
JOG Movement
0 to 1000
1 time
1
Immediately
Setup
7.5
Pn550
2
Analog Monitor 1 Offset Voltage
-10000 to
10000
0.1 V
0
Immediately
Setup
6.1.3
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When Enabled Classifi-
cation
Reference
Section
Program JOG Operation Switch
0
(Waiting time Pn535
→
Forward movement Pn531)
×
Number of movements Pn536
1
(Waiting time Pn535
→
Reverse movement Pn531)
×
Number of movements Pn536
2
(Waiting time Pn535
→
Forward movement Pn531)
×
Number of movements Pn536
(Waiting time Pn535
→
Reverse movement Pn531)
×
Number of movements Pn536
3
(Waiting time Pn535
→
Reverse movement Pn531)
×
Number of movements Pn536
(Waiting time Pn535
→
Forward movement Pn531)
×
Number of movements Pn536
4
(Waiting time Pn535
→
Forward movement Pn531
→
Waiting time Pn535
→
Reverse movement Pn531)
×
Number of movements Pn536
5
(Waiting time Pn535
→
Reverse movement Pn531
→
Waiting time Pn535
→
Forward movement Pn531)
×
Number of movements Pn536
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.