![YASKAWA Sigma-V Series Скачать руководство пользователя страница 402](http://html.mh-extra.com/html/yaskawa/sigma-v-series/sigma-v-series_user-manual_907687402.webp)
11 Appendix
11.2.2 Parameters
11-14
Pn008
2
Application Function Select
Switch 8
0000 to 7121
−
0000
After restart
Setup
−
Pn009
2
Application Function Select
Switch 9
0000 to 0111
−
0010
After restart
Tuning
−
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When Enabled Classifi-
cation
Reference
Section
Lowered Battery Voltage Alarm/Warning Selection
Reference
Section
0
Outputs alarm (A.830) for lowered battery voltage.
5.9.3
1
Outputs warning (A.930) for lowered battery voltage.
Function Selection for Undervoltage
Reference
Section
0
Does not detect undervoltage.
5.2.7
1
Detects warning and limits torque by host controller.
2
Detects warning and limits torque by Pn424 and Pn425. (Only in the SERVOPACK)
Warning Detection Selection
Reference
Section
0
Detects warning.
10.2.1
1
Does not detect warning (except for A.971).
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Reserved (Do not change.)
Current Control Method Selection
Reference
Section
0
Current control method 1
6.8.3
1
Current control method 2
Speed Detection Method Selection
Reference
Section
0
Speed detection 1
6.8.5
1
Speed detection 2
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.