![YASKAWA Sigma-V Series Скачать руководство пользователя страница 336](http://html.mh-extra.com/html/yaskawa/sigma-v-series/sigma-v-series_user-manual_907687336.webp)
9 Fully-closed Loop Control
9.1.1 System Configuration
9-2
9.1
System Configuration and Connection Example for
SERVOPACK with Fully-closed Loop Control
This section describes the system configuration and connection example for the SERVOPACK with fully-
closed loop control.
9.1.1
System Configuration
The following figure shows an example of the system configuration.
Note 1. The figure above shows a connection example of an external encoder. Refer to
1.6 Examples of Servo System
Configurations
for details on the power supply and peripheral devices.
2. In fully-closed loop control, rattling or twisting of mechanical parts may cause vibration, delaying the positioning
process.
SERVOPACK with Fully-closed Module
Servomotor main
circuit cable
Connection cable for
serial converter unit
External encoder cable
Serial converter unit
Model: JZDP-D00
-000-E
External encoder
(Not included)
Analog