![YASKAWA Sigma-V Series Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/yaskawa/sigma-v-series/sigma-v-series_user-manual_907687069.webp)
3.2 Connecting the Converter to the SERVOPACK
3-21
3
Wi
ring an
d Conn
ecti
on
3.2
Connecting the Converter to the SERVOPACK
3.2.1
Connecting the Connectors
Connect CN901 and CN103 on the SERVOPACK and converter as shown in the following figure.
3.2.2
Interconnecting Terminals
Use the busbars that are provided with the converter to connect the P and N terminals between the SERVO-
PACK and the converter.
The busbars are different for different converter models.
(1) SGDV-COA2BAA, -COA3ZDA Converters
Attach the busbars as shown in the following figure.
Note: The shapes of the ends of the busbars are different for the SERVOPACK and converter connections and for the P ter-
minal and N terminal connections.
SERVOPACK
Converter
CN901: I/O signal connector between the SERVOPACK and converter
CN103: Control power supply input connector
I/O signal connection cable
24-VDC control power supply cable
Analog
Cable Name
Cable Model
Cable Length
Description
IO signal connection cable JZSP-CVI02-A4-E
0.4 m
This cable connects the CN901 connectors on
the SERVOPACK and converter.
24-VDC control power
supply cable
JZSP-CVG00-A4-E
0.4 m
This cable connects the CN103(CN104) con-
nectors on the SERVOPACK and converter.