![YASKAWA Sigma-V Series Скачать руководство пользователя страница 426](http://html.mh-extra.com/html/yaskawa/sigma-v-series/sigma-v-series_user-manual_907687426.webp)
11 Appendix
11-38
Pn22A
0000
Fully-closed Control Selection
Switch
After restart
Pn281
20
Encoder Output Resolution
After restart
Pn300
600
Speed Reference Input Gain
Immediately
Pn301
100
Internal Set Speed 1
Immediately
Pn302
200
Internal Set Speed 2
Immediately
Pn303
300
Internal Set Speed 3
Immediately
Pn304
500
JOG Speed
Immediately
Pn305
0
Soft Start Acceleration Time
Immediately
Pn306
0
Soft Start Deceleration Time
Immediately
Pn307
40
Speed Reference Filter Time Con-
stant
Immediately
Pn310
0000
Vibration Detection Switch
Immediately
Pn311
100
Vibration Detection Sensibility
Immediately
Pn312
50
Vibration Detection Level
Immediately
Pn324
300
Moment of Inertia Calculating Start
Level
Immediately
Pn400
30
Torque Reference Input Gain
Immediately
Pn401
100
Torque Reference Filter Time Con-
stant
Immediately
Pn402
800
Forward Torque Limit
Immediately
Pn403
800
Reverse Torque Limit
Immediately
Pn404
100
Forward External Torque Limit
Immediately
Pn405
100
Reverse External Torque Limit
Immediately
Pn406
800
Emergency Stop Torque
Immediately
Pn407
10000
Speed Limit during Torque Control
Immediately
Pn408
0000
Torque Related Function Switch
∗
Pn409
5000
1st Notch Filter Frequency Immediately
Pn40A
70
1st Notch Filter Q Value
Immediately
Pn40B
0
1st Notch Filter Depth
Immediately
Pn40C
5000
2nd Notch Filter Frequency
Immediately
Pn40D
70
2nd Notch Filter Q Value
Immediately
Pn40E
0
2nd Notch Filter Depth
Immediately
Pn40F
5000
2nd Step 2nd Torque Reference Filter
Frequency
Immediately
Pn410
50
2nd Step 2nd Torque Reference Filter
Q Value
Immediately
Pn412
100
1st Step 2nd Torque Reference Filter
Time Constant
Immediately
Pn415
0
T-REF Filter Time Constant
Immediately
Pn423
0000
Reserved
−
Pn424
50
Torque Limit at Main Circuit Voltage
Drop
Immediately
Pn425
100
Release Time for Torque Limit at
Main Circuit Voltage Drop
Immediately
Pn456
15
Sweep Torque Reference Amplitude
Immediately
∗
The timing varies in accordance with the digit changed in a parameter (1st digit, 2nd digit, and so on). For details,
refer to
11.2.2 Parameters
.
(cont’d)
Parameter
Factory
Setting
Name
When
Enabled