11 Appendix
11.2.2 Parameters
11-28
Pn50C
2
Input Signal Selection 3
0000 to FFFF
−
8888
After restart
Setup
−
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When Enabled Classifi-
cation
Reference
Section
/SPD-D Signal Mapping
(Refer to
5.6 Internal Set Speed Control
.)
Reference
Section
0
Active when CN1-40 input signal is ON (closed).
5.6.1
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
Reserved (Do not set.)
8
Not active (fixed).
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
/SPD-A Signal Mapping
(Refer to
5.6 Internal Set Speed Control
.)
Reference
Section
0 to F
Same as /SPD-D Signal Mapping.
5.6.1
/SPD-B Signal Mapping
(Refer to
5.6 Internal Set Speed Control
.)
Reference
Section
0 to F
Same as /SPD-D Signal Mapping.
5.6.1
/C-SEL Signal Mapping (Control method change when ON (closed))
Reference
Section
0 to F
Same as /SPD-D Signal Mapping.
5.7.1
4th 3rd 2nd 1st
digit digit digit digit
n.