8. Connecting a host computer
8. Connecting a host computer
As a standard feature, the robot controller has an RS-232C interface port for data
communication with a host computer. Most computer models having an RS-232C port can
be interfaced to the robot controller, by connecting the COM connector on the front of
the robot controller to the RS-232C port of the computer using a communication cable.
For more detailed information on the RS-232C interface, see "RS-232C Interface" in
Chapter 7.
n
NOTE
D-SUB 9P (female) connector is for RS-232C interface.
■
Host computer connection
RCX221
XM
YM
MOTOR
RGEN
TEMP
ACIN
N
L
L1
N1
SAFETY
RPB
ROB
I/O
SD/COM
E-STOP
PIN11-12
EXT.E-STOP
OP.1
OP.2
!
SRV
ERR
RDY
COM connector
Host computer
25 pins 25 pins
or
9 pins
9 pins
9 pins
9 pins
COM port
Straight serial conversion adapter (option)
Communication cable (option)