![Yamaha CEmarking RCX221 Скачать руководство пользователя страница 264](http://html2.mh-extra.com/html/yamaha/cemarking-rcx221/cemarking-rcx221_user-manual_3060670264.webp)
4-196
Chapter
4
OPERA
TION
12. "SYSTEM" mode
■
Network setting (2)
SYSTEM
>PARAM>OP.BRD>SELECT
V9.00
1.board condition
VALID
2.IP address
3.Subnet mask
4.gateway
5.port No
192.168. 0. 2
255.255.255. 0
192.168. 0. 1
23
EDIT
JUMP
2) Select the parameter with the cursor (
↑
/
↓
) keys.
c
CAUTION
Changes you made to the IP address, subnet mask and gateway are
enabled after restarting the robot controller. When connecting the robot
controller to an existing network, always consult with the network
administrator for the IP address, subnet mask and gateway settings.
■
Network setting (3)
SYSTEM
>PARAM>OP.BRD>SELECT
V9.00
1.board condition
VALID
2.IP address
3.Subnet mask
4.gateway
5.port No
192.168. 0. 2
255.255.255. 0
192.168. 0. 1
23
EDIT
JUMP
3) The currently set parameters are displayed.
When changing the "Board condition" parameter, press
(INVALID) to disable
the Ethernet unit or press
(VALID) to enable the Ethernet unit.
When changing the communication mode, press
(OFFLINE) to set the offline
mode or press
(ONLINE) to set the online mode.
When changing other parameters, use
to
and
to make the setting and
press
.
4) Press
to quit the edit mode.
Содержание CEmarking RCX221
Страница 2: ......
Страница 6: ...4 MEMO...
Страница 16: ......
Страница 30: ......
Страница 38: ......
Страница 62: ...3 24 MEMO...
Страница 68: ......
Страница 228: ...4 160 Chapter 4 OPERATION 12 SYSTEM mode 5 Repeat the above steps 3 and 4 if necessary 6 Press to quit the edit mode...
Страница 342: ......
Страница 366: ...5 24 MEMO...
Страница 368: ......
Страница 384: ......
Страница 396: ......
Страница 404: ...8 8 MEMO...
Страница 406: ......
Страница 467: ...MEMO...