PARALLEL I/O INTERF
ACE
1.9.2 Emergency stop and servo ON
■
Emergency stop and servo ON
DI00
(in SAFETY
connector)
Emergency stop
ready signal
DO00
Emergency stop
contact monitor
MPRDY
(in SAFETY
connector)
Main power ON
ready
Main power
DO02
Servo-on state
DO03
Alarm
DI01
Servo ON
MIN 100msec
• To turn on the servo, DI00 (Emergency stop ready signal) in the SAFETY connector
must be on and the main power supply must be input.
• Wait at least 100msec after the main power is input before turning on DI01 (Servo
ON input).
• Turn off DI01 (Servo ON input) after making sure that DO02 (Servo-on state output)
is on.
1. Standard I/O interface overview