![Yamaha CEmarking RCX221 Скачать руководство пользователя страница 465](http://html2.mh-extra.com/html/yamaha/cemarking-rcx221/cemarking-rcx221_user-manual_3060670465.webp)
9-59
Chapter
9
TROUBLESHOOTING
Symptom
Possible cause
Check items
Corrective action
3
Position deviation
occurred.
• There are 2
main types of
position
deviation.
1.Electrical
position
deviation
2.Mechanical
position
deviation
In case 1, if
position
deviation
occurs, you can
perform return-
to-origin and
return to
original
position. In
case 2, you
cannot return
to original
position.
• Position sensor
device is defective.
• Cable is defective.
• Move axis in
emergency stop
and check the pulse
count.
• Replace motor if
count is incorrect.
• Replace cable if
found to be
defective.
• Position detection
error due to noise.
• Check grounding of
robot and controller.
• Check robot
periphery for noise.
• Check for noise
sources around
robot I/O cable.
• Ground the robot
and controller.
• Isolate from noise
sources around
robot.
• Isolate from noise
sources around
robot I/O cable.
• Mechanical error
occurred.
• Check the belt
tension
• Check for warping
or damage on
guides or ball
screws.
• Adjust to correct
tension if
necessary.
• Remove foreign
matter if found.
• Replace guides or
ball screws if
warping or damage
is found.
• Controller is
defective.
• Replace with
another controller
and check
operation.
• If operation is
normal use the
substitute
controller.
2. Troubleshooting
Содержание CEmarking RCX221
Страница 2: ......
Страница 6: ...4 MEMO...
Страница 16: ......
Страница 30: ......
Страница 38: ......
Страница 62: ...3 24 MEMO...
Страница 68: ......
Страница 228: ...4 160 Chapter 4 OPERATION 12 SYSTEM mode 5 Repeat the above steps 3 and 4 if necessary 6 Press to quit the edit mode...
Страница 342: ......
Страница 366: ...5 24 MEMO...
Страница 368: ......
Страница 384: ......
Страница 396: ......
Страница 404: ...8 8 MEMO...
Страница 406: ......
Страница 467: ...MEMO...