8. Unit select / PTUNIT
This parameter selects the point data unit system to be used when the controller is
started. For incremental specification robots and semi-absolute specification robots,
the current position is displayed in "pulse" units at controller startup because return-
to-origin is incomplete. When this parameter is used to select "mm" units, the
position display is switched to "mm" units at the same time when return-to-origin is
completed. This parameter is set to "Normal" when the parameters are initialized.
n
NOTE
• This parameter is supported by controllers of Ver. 9.08 onwards.
• Tool coordinate mode is enabled when the robot has an R-axis and the
hand installed on the R-axis is specifi ed by hand data. If the robot does
not have an R-axis or the hand installed on the R-axis is not specifi ed by
hand data, the unit system will be automatically changed to X (mm/°)
after start-up even if T (mm/°) is selected by parameter.
[Procedure]
1) Select "8. Unit select" in "SYSTEM>PARAM>OTHERS" mode.
2) Press
(EDIT).
The function key menu changes.
■
Setting "Unit select"
SYSTEM
>PARAM>OTHERS
V9.08
Normal J(pls)
X(mm/°) T(mm/°)
4.DO cond. on EMG HOLD
5.Incremental Mode INVALID
6.DI noise filter VALID
7.TRUE condition -1
8.Unit select Normal
3) Press a key from
(Normal) to
(mm/°) to enter the unit system.
Setting
Meaning
Normal (default setting)
Sets to the unit system that was last selected.
J (pls)
Sets to "pulses" unit system.
X (mm/°)
Sets "mm" unit system in normal setting (other
than tool coordinate mode).
T (mm/°)
Sets "mm" unit system in tool coordinate mode.
4) Press
to quit the edit mode.
Содержание CEmarking RCX221
Страница 2: ......
Страница 6: ...4 MEMO...
Страница 16: ......
Страница 30: ......
Страница 38: ......
Страница 62: ...3 24 MEMO...
Страница 68: ......
Страница 228: ...4 160 Chapter 4 OPERATION 12 SYSTEM mode 5 Repeat the above steps 3 and 4 if necessary 6 Press to quit the edit mode...
Страница 342: ......
Страница 366: ...5 24 MEMO...
Страница 368: ......
Страница 384: ......
Страница 396: ......
Страница 404: ...8 8 MEMO...
Страница 406: ......
Страница 467: ...MEMO...