4-224
Chapter
4
OPERA
TION
12. "SYSTEM" mode
12.3.3 SIO
settings
The serial I/O unit allows the master station sequencer (PLC) to send and receive parallel
port ON/OFF data in the robot controller I/O unit, regardless of the robot program. This
function allows using I/O devices such as sensors and relays as serial-connected devices.
n
NOTE
• Output results might be incorrect if the SIO specifi ed port is the same as
the port used by the program.
• These settings are only valid when the serial I/O unit is connected.
■
SIO overview
Master station
PLC
CC-Link
Remote device station
robot controller
I/O device
(sensors, relays. etc.)
Parallel I/O connection
The relation between parallel and serial ports that can be set are shown below.
Input devices such as sensors
Output devices such as valves
DI port
→
SO port
DO port
←
SI port
DI2()
SO2()
DO2()
SI2()
DI3()
SO3()
DO3()
SI3()
DI4()
SO4()
DO4()
SI4()
DI5()
SO5()
DO5()
SI5()
[Procedure]
1) Press
(SIO) in "SYSTEM>OPTION" mode.
■
SIO setting initial screen
SYSTEM
>OPTION>SIO
V9.00
1.Direct SI2()->DO2()
NO
2.Direct SI3()->DO3()
NO
3.Direct SI4()->DO4()
NO
4.Direct SI5()->DO5()
NO
5.Direct SO2()<-DI2()
NO
EDIT
JUMP
Содержание CEmarking RCX221
Страница 2: ......
Страница 6: ...4 MEMO...
Страница 16: ......
Страница 30: ......
Страница 38: ......
Страница 62: ...3 24 MEMO...
Страница 68: ......
Страница 228: ...4 160 Chapter 4 OPERATION 12 SYSTEM mode 5 Repeat the above steps 3 and 4 if necessary 6 Press to quit the edit mode...
Страница 342: ......
Страница 366: ...5 24 MEMO...
Страница 368: ......
Страница 384: ......
Страница 396: ......
Страница 404: ...8 8 MEMO...
Страница 406: ......
Страница 467: ...MEMO...