11. "MANUAL" mode
11.8.3
Checking the return-to-origin status
To check the status of return-to-origin, follow the procedure below.
[Procedure]
1) In "MANUAL" mode, press
(ORIGIN) to enter "MANUAL>ORIGIN" mode.
■
Checking the return-to-origin status
This screen shows the following information.
MANUAL
>ORIGIN
50% [MG] [SOHOJ]
––––––––––––––––––––––––––––––––––––––––
Press F.key to get axis for ORIGIN
M1 = NG / Sensor
M5= no axis
M2 =
/ TORQUE
M6= no axis
M3 =
M4 =
M1
M2
M3
M4
M5
OK
no axis
no axis
Axis
Return-to-origin status
"Origin method" parameter
(SYSTEM>PARAM>AXIS mode)
M1
(Axis 1)
NG (Origin incomplete)
SENSOR (Sensor method)
M2
(Axis 2)
OK (Return-to-origin complete)
TORQUE (Stroke end detection method)
No axis
The above information shows return-to-origin is incomplete on axis 1, but complete on
axis 2. The robot controller is in origin incomplete status, since not all axes performed
return-to-origin.
Valid keys
Menu
Function
F1
M1
Performs return-to-origin on axis 1.
F2
M2
Performs return-to-origin on axis 2.
F11
ALL
Performs return-to-origin on all axes.
Содержание CEmarking RCX221
Страница 2: ......
Страница 6: ...4 MEMO...
Страница 16: ......
Страница 30: ......
Страница 38: ......
Страница 62: ...3 24 MEMO...
Страница 68: ......
Страница 228: ...4 160 Chapter 4 OPERATION 12 SYSTEM mode 5 Repeat the above steps 3 and 4 if necessary 6 Press to quit the edit mode...
Страница 342: ......
Страница 366: ...5 24 MEMO...
Страница 368: ......
Страница 384: ......
Страница 396: ......
Страница 404: ...8 8 MEMO...
Страница 406: ......
Страница 467: ...MEMO...