6S35H11
2-8
9
8
7
6
5
4
3
2
1
Maintenance specification
Item
Unit
Model
250GET
L250GET
PTT system
Trim sensor
Trim sensor resistance
Ω
9–11
at 20°C (68°F) (P–B)
Resistance
Ω
248–388
at 20°C (68°F) (P–B)
Fluid type
ATF Dexron
2
Motor type
61A02
Output
kW
0.38
Brushes
Standard length
mm (in)
12.0 (0.47)
Wear limit
mm (in)
4.0 (0.16)
Commutator
Standard diameter
mm (in)
25.0 (0.98)
Wear limit
mm (in)
24.0 (0.95)
Standard undercut
mm (in)
1.8 (0.07)
Wear limit
mm (in)
1.2 (0.05)
Hydraulic pressure (down)
MPa (kgf/cm
2
)
4.7–6.7 (47–67)
Hydraulic pressure (up)
MPa (kgf/cm
2
)
11.3–13.3 (113–133)