TRBL
SHTG
9-7
6S35H11
Troubleshooting
Refer
Symptom 2
Cause 1
Cause 2
Checking step
to
page
Troubleshooting the PTT unit
Symptom 1: PTT unit does not operate
PTT switch malfunction
Check the PTT switch.
7-49
PTT relay does
not operate
—
Short, open, or loose
connection of the
wiring harness
Check the wiring har-
ness continuity.
*1
—
PTT relay malfunction
Check the PTT relay.
7-48
—
Short, open, or loose
connection of the PTT
motor lead
Check the PTT motor
lead.
*1
PTT motor does
not operate
Oil pressure
does not
increase
—
PTT motor malfunction
Disassemble and
check the PTT motor.
7-28
—
Blown fuse (80A)
Check the fuse (80A).
7-48
—
Loose connection of
the battery terminal
Check the battery ter-
minal
—
—
Discharged battery
Check the battery for
electrolyte level, gravity
and voltage.
3-14
—
Manual valve opened
Check the manual
valve.
—
Manual valve
malfunction
Insufficient PTT fluid
Add sufficient fluid.
3-11
—
PTT fluid leakage
Check the PTT unit for
leakage.
7-41
—
Clogged filter
Clogged fluid passage
Disassemble and
check the PTT unit.
7-34
—
*1
See the wiring diagram
6S35H11_09 05.9.30 15:01 Page 8
Содержание 250GETO
Страница 1: ...L250G SERVICE MANUAL 6S3 28197 5H 116 250G 250G L250G ...
Страница 4: ......
Страница 135: ... MEMO 9 8 7 6 5 4 3 2 1 6S35H11 5 48 ...
Страница 160: ...LOWR 6 23 6S35H11 Lower unit Shimming regular rotation model T3 M3 M4 M2 6S36050EA T2 T1 M1 F R P ...
Страница 201: ...6S35H11 6 64 9 8 7 6 5 4 3 2 1 MEMO ...
Страница 291: ......
Страница 292: ...YAMAHA MOTOR CO LTD Printed in Japan Aug 2005 1 4 1 E_2 Printed on recycled paper 250G L250G ...