XO FLOW – Installation instructions
60
6.3
Adjusting the pivoting joints of the bridge arm
The instrument bridge should be easy to move in the horizontal plane, and it should not
move by itself.
The instrument bridge arm has three pivoting joints.
Each pivoting joint has its own friction brake adjustable with Allen keys. See Figure 87, Figure 88 and
Figure 90.
The friction brake in the rear bridge arm is hidden behind the Ø150 mm cylindrical panel covering the
unit stand post. Remove the cover plug on the rear of the cylinder to access the friction brake. See
Figure 89.
Figure 87 – Adjusting the friction brake in the (rear) swivel joint using a 3 mm Allen key
Figure 88 – Adjusting the friction brake in the (front) swivel joint sing a 3 mm Allen key
Содержание FLOW
Страница 1: ...XO FLOW INSTALLATION INSTRUCTIONS...
Страница 2: ...2...
Страница 5: ...XO FLOW Installation instructions 5 10 One month follow up 71 11 Fuses 72 12 Symbols 72...
Страница 17: ...XO FLOW Installation instructions 17 Figure 15 Lifting the unit stand Figure 16 Adjusting the unit base...
Страница 35: ...XO FLOW Installation instructions 35 Figure 43 Fitting of lower outer cylinder...
Страница 38: ...XO FLOW Installation instructions 38 Figure 48 Positioning of the cables Figure 49 Securing the cables...
Страница 44: ...XO FLOW Installation instructions 44 Figure 58 Fitting the brake Figure 59 Fitting the cover plug...