Zynq-7000 AP SoC and 7 Series FPGAs MIS v4.1
494
UG586 November 30, 2016
Chapter 3:
RLDRAM II and RLDRAM 3 Memory Interface Solutions
An additional write/read is performed so the read bus is driven to a different value. This is
mostly required in hardware to make sure that the read calibration can distinguish the
correct data pattern.
After the third stage calibration completes,
init_calib_complete
is asserted, signifying
successful completion of the calibration process.
X-Ref Target - Figure 3-71
Figure 3-71:
Write and Read for Second Stage Read Calibration (Pattern Shown for RLDRAM II)
X-Ref Target - Figure 3-72
Figure 3-72:
Write and Read for Third Stage Read Calibration (Pattern Shown for RLDRAM II)