1125100
WPC 1000 User Manual
G-2
Glossary
depth penetration factor
A value used in the ANSI formula for calculating the safety
distance. The depth penetration factor is a measure of how far
an object, like an operator’s hand, can move through the light
curtain before the light curtain reacts.
dual diverse redundancy
A WPC 1000 feature in which both microprocessor systems
belong to different architectures, are programmed using
different programming languages, function independently of
one other, have separate power supplies, and provide different
information to the operator. Dual diverse redundancy provides
optimum clutch/brake control and operator safety.
Dual Safety Valve
The control-reliable device on the press that controls the flow
of air to the press’s clutch.
emergency stop
A signal sent to the press in response to a malfunction that
stops the press immediately. An Emergency Stop can be
initiated manually by the operator or automatically by WPC
1000 or external devices.
fault (error) message
An alphanumeric code that appears on the WPC 1000 display
when an error condition occurs.
hand-speed constant
A value used in the ANSI formula for calculating the safety
distance. The hand-speed constant is the distance one can
theoretically move one’s hand and arm in one second. OSHA
recommends a hand-speed constant of 63 inches-per-second.
interrupted stroke
A condition that occurs when the press has been Emergency-
stopped before the completion of the stroke by either the
operator or an automatic device for personnel or equipment
protection. During an interrupted stroke condition, the
Interrupted Stroke LED on the WPC 1000 display flashes.
lockout
A WPC 1000 function that prevents the press from being
restarted after clearing of fault messages that indicate serious
errors. The lockout condition is indicated by the lockout
message, which appears on the WPC 1000 display. Lockout
provides an added safety feature to the WPC 1000.
lockout message
A message (i.e., “Loc”) that appears on the WPC 1000 display
indicating that a serious error condition has occurred.
Micro-inch
A WPC 1000 feature that allows the operator to set the amount
of time in milliseconds that the Dual Safety Valve is open and,
therefore, the distance the ram will travel when the Run/Inch
switches on the Operator Station are pushed in Inch mode.
Micro-inch is designed for high-speed and/or short-stroke
presses.
NEMA 12
A rating certifying that an electrical device is protected against
dust, water, and oil.
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......