WPC 1000 User Manual
1125100
Glossary
G-3
ninety degree (90)° stop-
time test
A test required to set the proper safety distance for personnel-
guarding devices, including light curtains, two-hand controls,
and type-B movable barriers. This test checks the stopping
time of the press at its most critical stopping point, normally
the midpoint of the downstroke (i.e., 90°), while the press is
running in Continuous mode (or Single-stroke if the press does
not have a selector setting for Continuous). Stopping time is a
value required in the ANSI formula for calculating the safety
distance.
object sensitivity
A value required in deriving the depth penetration factor for a
light curtain. Object sensitivity specifies the smallest diameter
object that a light curtain will detect anywhere in its field.
ON-OFF setting
Stroke angle settings at which the cam channel is to turn ON
(activate) and turn OFF (deactivate)
OSHA
Stands for Occupational Safety and Health Administration, a
government agency that has established regulations for
mechanical power presses including presence-sensing devices
for point-of-operation guarding.
overrun limit switch
A device mounted on the press to check the accuracy of the
crankshaft angle maintained by the resolver. The overrun limit
switch consists of a magnet, which is mounted on the
crankshaft (or other shaft), and a stationary magnetic switch,
which is mounted just above the magnet so that it detects the
magnetic field on every stroke. The magnetic switch is also
called an “overrun sensor.”
WPC 1000 checks the resolver crankshaft angle by comparing
it to the signal received from the overrun limit switch. When
the signal is not received at the same resolver angle on every
stroke, WPC 1000 knows that the resolver is no longer rotating
at a 1:1 ratio with the press.
overrun timing
A WPC 1000 feature that provides a backup for Top-stop
timing, stopping the press if the Top-stop output relay should
fail. Overrun timing is a function of the stopping time of the
press and is influenced by the condition of the brake linings
and press speed. It is also dependent on proper installation of
the overrun limit switch.
palm time
The length of time within which the two palm switches on
each Operator Station connected to WPC 1000 must be
activated in order to start the press. This interval is 1/2 (0.5)
second as required by ANSI. If the palm time on any Operator
Station is exceeded, the press will not start. ANSI standards
refer to the palm time as synchronous time.
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......