Initialization, Setup, and Checkout
3-43
•
If the ram does not move at all, check to make sure that the correct version of WPC
1000 firmware is installed, and check the wiring of the palm buttons, correcting any
problems. Re-run the test, starting with step 1. If the ram still does not move when you
press the Run/Inch palm buttons, call Wintriss Tech. Support.
4.
Interrupt the light curtain by placing a piece of cardboard or other object between the light
curtain heads to block at least two inches of the light field. Leave the object in place while
you perform step 5.
5.
Press and hold both Run/Inch palm buttons, observing the behavior of the ram.
•
If the ram does not move and you have only one light curtain, go to the next step.
•
If the ram does move, check to make sure the correct version of WPC 1000 firmware is
installed and check the wiring of the palm buttons and light curtains, correcting any
problems. Re-run the test, starting with step 4. If the ram still moves with the light
curtain blocked, call Wintriss Tech. Support.
6.
Remove the object you used to interrupt the light curtain field in step 4. Prepare to insert
it into the field while the ram is on the downstroke. Be sure to keep hands and other
objects away from the press.
7.
While one person presses and holds both Run/Inch palm buttons, have another person
move the cardboard or other object into the light field while the ram is on the downstroke.
Observe the action of the ram.
•
If you are using one light curtain, and the ram stops immediately and the Interrupted
Stroke LED flashes, go to the next step.
•
If you are using two light curtains, and the ram stops immediately and the Interrupted
Stroke LED flashes, inch the ram to the top of the stroke and repeat the test, starting
with step 6, by interrupting the second light curtain. When you have successfully
completed the test with the second light curtain, go to the next step.
•
If the ram does not stop immediately, check the wiring of the light curtains, correcting
any problems; then, Inch the ram to the top of the stroke and re-run the test, starting with
step 6. If the ram again moves when the light curtain is interrupted, call Wintriss Tech.
Support.
8.
Clear the Interrupted Stroke by holding the Run/Inch palm buttons until the ram stops at
top dead center.
9.
Press and immediately release the Run/Inch palm buttons, observing the behavior of the
ram.
•
If the ram moves when you press the Run/Inch palm buttons, then stops when you
release them, and the Interrupted Stroke LED flashes, go to the next step.
•
If the ram does not move, or if it moves but does not stop immediately when you release
the Run/Inch palm buttons, or if the Interrupted Stroke LED does not flash, check the
wiring of the palm buttons and light curtains, correcting any problems, and run this test
again, repeating step 9. If the ram still does not move or moves but does not stop
immediately, or if the ram stops but the Interrupted Stroke LED does not flash, call
Wintriss Tech. Support.
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......