Wiring WPC 1000 User Inputs
WPC 1000 user inputs allow you to connect signals from other equipment in order to monitor
auxiliary press functions such as lubrication systems. WPC 1000 provides connections for a
pair of control-reliable, cross-checked inputs and two independent inputs that are not control
reliable.
When one of these inputs issues a Stop command by opening a normally closed (N/C) relay, a
fault code for the input(s) appears on the LED display. User input 1 issues an Emergency-stop
command, user input 2 generates a Top-stop, and the cross-checked input pair 3A and 3B
generates an Emergency Stop, simultaneously opening the Lockout relay and displaying the
“Loc” message on the digital LED readout. The stop type, fault code, and wiring connections
for each input are shown in Table 2-3, page 2-29.
USER INPUTS 1 AND 2 NOT SUITABLE FOR SAFETY USE
DO NOT use inputs 1 and 2 as part of any personnel-protection system. These inputs are not
control reliable.
Failure to comply with these instructions will result in death or serious injury.
USER INPUTS ADD DELAY TO STOPPING TIME
DO NOT connect light curtains or other presence-sensing devices to any user inputs. The cross-
checked input pair (3A and 3B), though control reliable, is suitable only for applications such as
connecting to safety switches used with interlocking barrier guards.
Failure to comply with these instructions will result in death or serious injury.
MAKE SURE TO WIRE CROSS-CHECKED INPUT PAIR CORRECTLY
Input pair 3A and 3B are control reliable only if wired correctly in a pair according to the
instructions in this section.
Failure to comply with these instructions will result in death or serious injury.
CHECK PRESS TO MAKE SURE IT STOPS WHEN USER INPUT ACTUATES
• WPC 1000 comes from the factory with the inputs bypassed by jumpers. Make sure to remove
the appropriate jumper from the Control board connector when you wire a user input.
Otherwise, WPC 1000 will not receive the signal from the input. Leave all unused inputs
jumpered/bypassed.
• Perform checkout procedures to ensure that the user inputs are wired correctly and that WPC
1000 responds correctly when the user input faults (see page 3-54).
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
DANGER
!
DANGER
!
DANGER
!
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......