Test safeguarding devices as follows:
1.
Run the press in Inch mode. Block the light curtain, if one is installed, with an opaque
object. The press should stop immediately.
•
If the press stops, go to the next step.
•
If the press does not stop, check the wiring of the light curtain and correct any problems.
Repeat the test. If the press still doesn’t stop, call Wintriss Tech. Support.
2.
Run the press in Inch mode. Keeping hands outside the guarded area, open one of the
moveable guards just enough to open the interlock switch. The press should stop
immediately.
•
If the press stops immediately when you open the guard, go to the next step.
•
If the press does not stop, check the wiring of the moveable guard and correct any
problems. Repeat the test. If the press still doesn’t stop, call Wintriss Tech. Support.
3.
Close the guard you just tested, reset the press control, and repeat step 2 for each
moveable guard. When you have tested all moveable guards, go to the next section.
Checking Dual Safety Valve (DSV) Wiring
Follow the checkout procedure below to ensure that the dual safety valve is wired correctly.
Proper installation and operation of the DSV is crucial to personnel safety.
1.
Power down the press and press control.
2.
On the DSV/Lockout Relay board, which is installed in the lower right corner of the WPC
1000 Control board (see Figure 2-11, page 2-20), remove fuse F302 or F303. F302 and
F303 are the DSV fuses.
3.
Power up the press and press control, select INCH with the Stroke Select switch, and push
both Run/Inch buttons. Observe what happens.
•
If the ram does not move and the display shows F79 or one of the DSV faults (see
page 5-14), the DSV is operating properly. Go to the next step.
•
If the ram moves and/or the display shows a fault other than F79 or one of the DSV
faults, check the wiring of the DSV and correct any problems, then repeat step 3. If the
ram still moves and/or the display still shows a fault other than F79 or one of the DSV
faults, power down the press immediately, and call Wintriss Tech. Support.
4.
Power down the press and press control.
5.
On the DSV/Lockout Relay board, replace the DSV fuse (i.e., F302 or F303) you removed
in step 2, and remove the other DSV fuse.
PREVENT ELECTRIC SHOCK WHEN WORKING INSIDE THE ENCLOSURE
Turn off and disconnect power from the WPC 1000, the press and any other machinery it is
connected to before working inside the enclosure. This includes power to the press motor.
Failure to comply with these instructions could result in death or serious injury.
WARNING
!
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......