1125100
WPC 1000 User Manual
3-42
Initialization, Setup, and Checkout
Single-stroke Mode Test with Light Curtain(s)
To test Single-stroke mode when light curtains are installed, perform the following steps,
referring to Figure 3-14, page 3-36 for LED locations on the WPC 1000 Control board:
1.
Set the Stroke Select switch to “SINGLE,” and verify that the “Single-stroke select” LED
on the WPC 1000 Control board is lit.
2.
Verify that the light curtain is unobstructed and that the “Light curtain input 1” and “Light
curtain input 2” LEDs are lit. These LEDs turn off when the light curtain is obstructed.
3.
Press and hold both Run/Inch palm buttons on the Operator Station, observing the ram’s
motion.
•
If the ram makes a complete stroke, stopping at top dead center, go to the next step.
•
If the ram moves but does not make a complete stroke or does not stop at top dead
center and a fault code between F80 and F89 (or between H80 and H89) displays, there
is a problem with the overrun limit switch. Try the remedies suggested for overrun limit
switch faults, starting on page 5-16; then, Inch the ram to the top of the stroke and
repeat this test. If the ram still does not make a complete stroke or does not stop at top
dead center, call Wintriss Tech. Support.
•
If the ram moves but does not make a complete stroke or does not stop at top dead
center and an overrun limit switch fault does not display, check the wiring of the palm
buttons and light curtains, correcting any problems; then, Inch the ram to the top of the
stroke, and repeat the test. If the ram still does not make a complete stroke or does not
stop at top dead center, call Wintriss Tech. Support.
INJURY DURING TESTING
• Keep all personnel away from the press during testing.
• Be sure there is no die or other tooling in the press during testing.
Failure to comply with these instructions will result in death or serious injury.
CONTINUOUS MODE USED ON PRESS NOT GUARDED PROPERLY FOR CONTINUOUS
Disconnect the “Continuous” position on the Stroke Select switch to prevent your press from being
run in Continuous mode if it is not guarded correctly for use in Continuous mode. Also cover the
“CONT” label on your control’s Stroke Select switch.
Failure to comply with these instructions will result in death or serious injury.
ELECTRIC SHOCK HAZARD WHEN WORKING INSIDE ENCLOSURE WITH POWER ON
• DO NOT touch electrical connections or circuit boards.
• Ensure that this test is performed by qualified personnel.
Failure to comply with these instructions could result in death or serious injury.
DANGER
!
DANGER
!
WARNING
!
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......