1125100
WPC 1000 User Manual
3-48
Initialization, Setup, and Checkout
5.
Press the Emergency Stop button on the Operator Station. The ram should stop
immediately, the F13 fault code should appear in the LED display, and the Interrupted
Stroke LED should flash. If these conditions are not present, check the wiring of the
Operator Station, particularly the E-stop wiring, and correct any problems. Rerun this test
from step 4. If the conditions are still not present, call Wintriss Tech. Support.
6.
Press and hold the Run/Inch palm buttons until the press returns to top dead center.
7.
Press the Prior Act button and, before the indicator lamp goes out, press both Run/Inch
palm buttons, releasing them after bottom dead center on the first stroke. The press should
continue running.
8.
Press the Reset/Select button until the “Stopping Time” indicator segment becomes lit.
9.
Press the Top Stop button on the Operator Station. The ram should stop near top dead
center, and the Stopping Time in milliseconds should appear in the LED display.
10.
Restart the press in Continuous mode.
11.
Block the light curtain. The press should come to an immediate stop, and the Interrupted
Stroke LED should flash.
•
If the press comes to an immediate stop and the Interrupted Stroke LED flashes, go to
the next step.
•
If your WPC 1000 has the muting option, and the ram stops as soon as it reaches the
non-muted (i.e., downward) portion of the stroke, go to the next step.
•
If your WPC 1000 has the muting option, and the ram does not stop in the non-muted
portion of the stroke, check the wiring of the light curtain, correcting any problems, and
run the test again, starting with step 10. If the ram still does not stop in the non-muted
part of the stroke, call Wintriss Tech. Support.
•
If your WPC 1000 does not have the muting option and the press does not come to an
immediate stop when you interrupt the light curtain, check the wiring of the light
curtain, correcting any problems, and run the test again, starting with step 10. If the
press still does not stop immediately, call Wintriss Tech. Support.
12.
Press and hold both Run/Inch palm buttons to return the ram to top dead center.
13.
Go to the next applicable test.
RESET EMERGENCY-STOP BUTTON AFTER USE
The Emergency-stop button is not spring-loaded. You must pull it up to its original position
to reset the Emergency-stop (F13) fault.
When a stroke is interrupted, WPC 1000 automatically switches to Two-hand Maintained
Single-stroke mode for the remainder of the stroke.
NOTICE
NOTICE
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......