1125100
WPC 1000 User Manual
3-24
Initialization, Setup, and Checkout
When using the ANSI formula, be sure to perform the calculations in this order:
(1) Add Ts + Tc + Tr + Tbm first.
(2) Multiply the result by 63.
(3) Add this result to Dpf. This is Ds.
If you do no follow this order, your safety distance calculation will be incorrect.
OSHA Safety Distance Formula
The OSHA safety distance formula as specified in OSHA 1910.217 is
Ds = K x Ts
where
Ds is the OSHA safety distance in inches
K is the OSHA-recommended hand-speed constant of 63 inches per second
Ts is the stopping time of the press in seconds
The hand-speed constant indicates how far you could theoretically move your hand and arm in
one second.
The Stopping Time of the press (Ts) is measured at approximately 90° of crankshaft rotation,
or at maximum closing velocity. In addition to the Stopping Time of the press, the OSHA Ts
value must include the following factors:
•
Response time of the press control that activates the brake
•
Response time of the light curtain
•
Additional time (Tbm) added to the Stopping Time to compensate for brake wear
The response time of the press control is included in the result of the 90° stop-time test run on
the WPC 1000 (see Determining the 90° Stop Time, page 3-18).
Response times of Shadow light curtains are shown in Table 3-4, page 3-22.
Calculation of the Tbm value is described in Calculating the Stop-time Limit, page 3-16.
INCORRECT SAFETY DISTANCE
Use the Stopping Time measured in the 90° stop-time test. If you do not do this, the safety
distance may be too small to allow the press to stop before someone reaches the hazardous area.
See Determining the 90° Stop Time, page 3-18 for instructions on performing this test.
Failure to comply with these instructions will result in death or serious injury.
Wintriss recommends that you use the American National Standards Institute (ANSI) formula for
calculating safety distance because it contains more factors, allowing you to calculate the safety
distance more precisely. The ANSI formula is explained in the previous section (see page 3-22).
DANGER
!
NOTICE
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......