WPC 1000 User Manual
1125100
Initialization, Setup, and Checkout
3-49
Continuous Mode Test without Light Curtain(s)
This test verifies that your press operates correctly in Continuous mode. To verify
Continuous mode operation on a press with light curtains, return to the previous test (see
page 3-47). If your press does not run in Continuous mode, go to the next applicable test. To
run the Continuous mode test without light curtain, do the following, referring to Figure 3-14,
page 3-36 for LED locations on the WPC 1000 Control board:
1.
Set the Stroke Select switch to “CONT.” Verify that the “Continuous select” LED on the
WPC 1000 Control board is lit.
2.
Press the Prior Act button on the Operator Station. The Prior Act lamp should illuminate,
then turn off after eight seconds.
•
If the Prior Act lamp turns off after eight seconds, go to the next step.
•
If the Prior Act lamp does not turn off after eight seconds, stop! Do not go any further!
Call Wintriss Tech. Support.
3.
Press the Prior Act button and, before the indicator lamp goes out, press both Run/Inch
palm buttons, releasing them after bottom dead center on the first stroke. The press should
continue running.
•
If the press continues to run, go to the next step.
•
If the press stops, check the wiring of the palm buttons, and correct any problems. Run
the test again. If the press still stops, call Wintriss Tech. Support.
4.
Press the Emergency Stop button on the Operator Station. The ram should stop
immediately, the F13 fault code should appear in the LED display, and the Interrupted
Stroke LED should flash. If these conditions are not present, check the wiring of the
Operator Station, particularly the E-stop wiring, and rerun this test from step 3. If the
conditions are still not present, call Wintriss Tech. Support.
IMPROPER SAFEGUARDING
• Install safeguarding devices as needed to ensure operator safety. Follow the machine guarding
requirements of OSHA regulation 1910.217 and any other regulations and standards that apply.
• Ensure that guarding is properly installed to prevent access to the machine over, under or
around any guarding device.
Failure to comply with these instructions will result in death or serious injury.
INJURY DURING TESTING
• Keep all personnel away from the press during testing.
• Be sure there is no die or other tooling in the press during testing.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
DANGER
!
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......