WPC 1000 User Manual
1125100
Initialization, Setup, and Checkout
3-45
•
If the ram moves when you press the Run/Inch buttons, then stops when you release
them, and the Interrupted Stroke LED flashes, go to the next step.
•
If the ram does not move, or if it moves but does not stop immediately when you release
the Run/Inch buttons, or if the Interrupted Stroke LED does not flash, check the wiring
of the palm buttons and light curtains, correcting any problems, and run the test again,
repeating step 5. If the ram still does not move or moves but does not stop immediately,
or if the ram stops but the Interrupted Stroke LED does not flash, call Wintriss Tech.
Support.
6.
Complete the stroke by pressing and holding the Run/Inch palm buttons.
7.
Go to the next applicable test.
Anti-tiedown Test
The anti-tiedown test verifies that the Operator Station is installed correctly and is wired so
that both hands are needed to press the Run/Inch buttons simultaneously. To perform the test,
do the following:
1.
Set the Stroke Select switch to “SINGLE.”
2.
Press and hold down both Run/Inch palm buttons to cycle the press through one stroke.
When the press top-stops, continue to hold down the left button, and remove your hand
from the right button; then, after a moment, replace your hand on the right button and
continue to hold down both buttons.
•
If the press does not initiate the stroke, go to the next step.
•
If the press does initiate the stroke, check the wiring of the palm buttons. When the
problem has been corrected, repeat step 2. If the press still initiates the stroke, call
Wintriss Tech. Support.
INJURY DURING TESTING
• Keep all personnel away from the press during testing.
• Be sure there is no die or other tooling in the press during testing.
Failure to comply with these instructions will result in death or serious injury.
OPERATOR STATION MAY NOT MEET SAFETY REQUIREMENTS
• Ensure that the Operator Station is wired correctly.
• Ensure that on any non-Wintriss Operator Station the Run buttons are placed so that two hands
are required to push both buttons at the same time and no one can press both buttons with one
hand or with one hand and one elbow.
• Ensure that on any non-Wintriss Operator Station the Run buttons have ring guards or other
means in place to prevent unintentional operation.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
DANGER
!
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......