1125100
WPC 1000 User Manual
3-44
Initialization, Setup, and Checkout
10.
Complete the stroke by pressing and holding the Run/Inch palm buttons.
11.
Go to the next applicable test.
Single Stroke Mode Test Without Light Curtain(s)
To test Single-stroke mode when light curtains are not installed, perform the following steps,
referring to Figure 3-14, page 3-36 for LED locations on the WPC 1000 Control board:
1.
Set the Stroke Select switch to “SINGLE.” Verify that the “Single-stroke select” LED on
the WPC 1000 Control board is lit.
2.
Press and hold both Run/Inch palm buttons, observing the motion of the ram.
•
If the ram makes a complete stroke and stops at or near top dead center, go to step 6.
•
If the ram does not make a full stroke or does not stop at top dead center, go to the next
step.
3.
Check for fault codes on the LED display.
•
If a fault code between F80 and F89 (or between H80 and H89) is displayed, there is a
problem with the overrun limit switch. Try the remedies suggested for overrun limit
switch faults, starting on page 5-16; then, Inch the ram to the top of the stroke and run
the test again, starting with step 2. If the ram still does not make a complete stroke or
does not stop at top dead center, call Wintriss Tech. Support.
•
If the LED display is blank or shows an error other than an overrun limit switch fault,
check and correct the wiring of the palm buttons and light curtains, correcting any
problems; then, run the test again, starting with step 2. If the ram still does not complete
a stroke or stop at top dead center, call Wintriss Tech. Support.
4.
Turn the Stroke Select switch to “INCH,” and bring the ram to top dead center.
5.
Press and then immediately release the Run/Inch palm buttons, observing the behavior of
the ram.
INJURY DURING TESTING
• Keep all personnel away from the press during testing.
• Be sure there is no die or other tooling in the press during testing.
Failure to comply with these instructions will result in death or serious injury.
CONTINUOUS MODE USED ON PRESS NOT GUARDED PROPERLY FOR CONTINUOUS
Disconnect the “Continuous” position on the Stroke Select switch to prevent your press from being
run in Continuous mode if it is not guarded correctly for use in Continuous mode. Also cover the
“CONT” label on your control’s Stroke Select switch.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
DANGER
!
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......