WPC 1000 User Manual
1125100
Initialization, Setup, and Checkout
3-15
3.
With the press in Inch mode, press the Reset/Select button repeatedly until the “Auto
Carryup” indicator is lit.
4.
Adjust the Auto Carry-up Angle by turning the WPC Settings key switch to “+”
(counterclockwise) to increase the value or to “–” (clockwise) to decrease the value.
5.
When the value you want is shown in the LED display, save your setting by pressing the
Reset/Select button until the “Angle/SPM” indicator is lit.
6.
Set option switch 7 to ON to disable changes to the Auto Carry-up Angle (see step 1).
7.
Power down WPC 1000, then power the unit back up to enable the new setting.
Running Brake Monitor Tests and Making Settings
WPC 1000’s built-in brake monitor constantly checks the condition of the brake by measuring
the Stopping Time each time the press top-stops. Stopping time is the amount of time in
milliseconds that it takes the crankshaft to stop once the Dual Safety Valve (DSV) has been
de-energized. When the “Stopping Time” indicator is lit, the Stopping Time of the press on
the most recent stroke is shown in the LED display.
The Stop-time Limit is a setting used by the brake monitor to determine when the press needs
to be stopped to alert the operator to the need for brake repair. The Stop-time Limit is
factory-set to 500 milliseconds.
Determining the Stopping Time of Your Press
First, you need to determine the Stopping Time of your press at Top-stop. To do so, perform
the following steps:
1.
Install the heaviest upper die in your press. Adjust the counterbalance for ram weight (if
the press has a counterbalance).
2.
Turn power on to the WPC 1000, and observe the current crankshaft angle shown in the
LED display.
3.
Run the press in Continuous mode by turning the Mode Select switch to “CONT,” and
check the press speed shown in the LED display. If you have the optional counter display,
you will have to select the “Angle/SPM” indicator segment, using the Reset/Select button.
If your press does not run in Continuous, initiate a stroke with the Mode Select switch set
to “SINGLE.”
INCORRECT STOP-TIME LIMIT
Determine the Stopping Time and set the Stop-time Limit at a value that reflects the actual
Stopping Time of your press. Use the stop time measured in the 90° stop-time test to calculate the
safety distance.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......